Installing and Configuring Your AV Equipment
16
N3000 Series User Manual
NOTE:
If the LocalPlay screen does not appear, refer to Chapter 5, Troubleshooting for more guidance.
NOTE:
In order for the unit to receive PoE, it must be connected to a switch or other equipment that has a PoE PSE (Power Sourcing
Equipment) port. PoE does not pass through the daisy chain (P1) port.
CAUTION:
Do not run wiring that is connected to a PoE PSE port outside of the building where the PSE resides. It is for intra-building
use only.
Step 3: Connecting Encoders to the Network and Configuring Stream
Settings
1.
Using a Cat-5 cable, connect your SVSI Encoder’s
P0
port to a PoE-enabled switch. In non-PoE applications connect a 12V
regulated power supply (N9312) to the two-pin terminal block plug connector (labeled
+12V 2A
).
NOTE:
In order for the unit to receive PoE, it must be connected to a switch or other equipment that has a PoE PSE port.
2.
In
N-Able
, select the
Unit
Management
tab and click the
Auto
Discover
button (if the table has not already populated itself
with the installed units). See
Figure 12
.
FIG. 12
Unit Management Page
3.
Find your Encoder in the list. N3000 units are displayed on the following tabs:
•
Unit
Management
tab — N3000 units have
N3000 Encoder/Decoder
listed in their
Type
fields.
•
Video Matrix
tab — N3000 units are found on the
N3000
sub-tab (as shown in
Figure 13
).
NOTE:
If using multiple Encoders in your set up, it is important to plug in and configure one Encoder at a time. All Encoders come pre-
configured to use stream 1. As you add Encoders to the network, you will need to set them up to use different streams.