Failed AC power fuse in rear of unit

Unplug the loop and AC power supply from amplifier, and replace the failed fuse with the spare fuse 

in AC power input fuse tray . 
Reconnect the AC power supply and switch on . If the fuse fails again, return the unit to Ampetronic 

for evaluation - it may well be covered under warranty, which will be invalidated by removing the 

cover . If the fuse does not fail a 'loop error' may be indicated, but shows that the unit is working 

correctly . Re-connect the loop and switch the power off then on again to reset loop error .
If the fuse fails when the loop is re-connected to the unit, then the loop could be shorted to 

electrical mains (and building) earth. This can happen even if no audio signal is present, as the 

short to earth is likely to cause an instability / oscillation / feedback condition to develop . A loop 

cable short to earth most commonly occurs where flat copper tape is installed on a metal-clad 

raised access flooring system. If the insulation on the flat copper tape is abraded (for example by a 

piece of metal swarf trapped below the copper tape), the conductor could short to the earthed tiles.
When installing on raised access floors, it is advisable to insulate beneath the flat copper tape 

installation using Ampetronic PWT or similar tape .
The loop short to earth may only be completed when a person steps on the tape in the affected 

location, which can create significant difficulties when diagnosing the cause of fuse failure. Contact 

Ampetronic for further advice if a unit is suffering recurring but untraceable failure of the rear panel 

fuse .

14. UPDATING FIRMWARE & WEB INTERFACE

N.B. Driver firmware and Web Interface software must be updated at the same time as the 

version must match .

Updating Firmware

a) Contact Ampetronic for the appropriate version to copy to a USB Stick. 
b) Insert USB Stick into rear of unit and power up,
c) Wait for the display to show ‘PLS REMOVE STICK AND CYCLE POWER’

Updating Web Interface

a) Contact Ampetronic for the latest .bin file
b) Browse to the IP Address of the Web Interface and enter the URL extension /mpfsupload
c) Choose file and upload
d) Wait for the message ‘MPFS Update Successful’ to be displayed and follow the ‘Site main page’  

    link

15. ACCESSORIES

Rack mounting unit blank
10mm wide, 0 .1mm / 18mm wide, 0 .25mm / 20mm wide, 0 .15mm thick copper cable/tapes
Direct Burial Cable
Printed Warning Tape

WiFi Kit (Nano Router, Battery, USB cable, Ethernet cable)

Details of all products and services provided by Ampetronic can be found at www .ampetronic .co

Содержание d series

Страница 1: ...D Series Installation Handbook User Guide www ampetronic co...

Страница 2: ......

Страница 3: ...ure 13 Test Signal Menu Structure 13 MLC Menu Structure 14 Settings Menu Structure 15 Diagnostics Menu Structure 16 Ethernet Menu Structure 17 Quick Menu Structure 19 8 Ethernet Interface 20 Settings...

Страница 4: ...connector may be used to maintain safety Cables incorporating the UK 13A fused plug Schuko with earthing contacts and UL approved grounding type are acceptable These must be plugged into power outlets...

Страница 5: ...essing units See Accessories or contact Ampetronic for advice The D Series range consists of dual and single loop output class D drivers meaning a 60 increase in energy efficiency over previous soluti...

Страница 6: ...ment sufficient airflow into the enclosure must be provided through vents fans or other means such that the units exhaust air is not recycled to the inlet causing a reduction in output current and tri...

Страница 7: ...e desired level of performance A pair of headphones with a 3 5mm jack plug connection is also useful to monitor the loop signal System Requirements The induction loop cables should be already installe...

Страница 8: ...V Power OFF Ethernet Parameters Set by DHCP MLC OFF The D Series drivers have their adjustment set in decibels dB A setting of 0dB equates to maximum current or to maximum input gain A value of less t...

Страница 9: ...sinewave combi 1K signal combi 1 6 kHz and combi 2 5 kHz These signals over ride the inputs on the back of the driver Switching off the test signals routes the sum of the signals on inputs 1 and 2 to...

Страница 10: ...ons MENU NAVIGATION FORWARD BACK Scroll though the list of set up options MENU NAVIGATION SELECT Select to enter sub menu for further set up options LCD DISPLAY SCREEN Displays amplifier model configu...

Страница 11: ...for ancillary units configurable for fault reporting SLAVE I O 3 pole 6 4mm jack insert point for use with ancillaries or to string drivers SERIAL NUMBER For use when registering your warranty or repo...

Страница 12: ...select this 6 times within 5 seconds to lock unlock the menu Adds to numerical values or moves up a list of values Subtracts from a numerical value or moves down a list of values Each button except th...

Страница 13: ...ns turns on to show that a value can be altered Editing Values If the value being edited is a numerical value then the cursor will flash over the digit that will be altered by pressing the INCREMENT o...

Страница 14: ...put 1 Gain 1 1 Input 1 Gain Gain XX X dB 1 2 Input 1 Mode MIC Phantom 1 2 Input 1 Mode MIC 1 2 Input 1 Mode Line 1 3 Input 2 Gain Gain XX X dB 1 2 Input 2 Mode MIC Phantom 1 2 Input 2 Mode MIC 1 2 Inp...

Страница 15: ...t A B 2 Current Set 2 2 Cur Offset B Tier 2 Test Signal Menu Structure Bold items are flashing and adjustable Main Menu 3 1 Signal Type Off 3 1 Signal Type Combi 3 1 Signal Type Continuous 3 1 Signal...

Страница 16: ...he MLC into Custom Setting mode Main Menu 4 1 MLC Preset Off 4 1 MLC Preset 0 25dB 4 MLC 4 1 MLC Preset 4 1 MLC Preset 4 00dB 4 1 MLC Preset Custom Setting 0 25 to 4dB octave 4 MLC 4 2 Custom Low 4 2...

Страница 17: ...turn No Change 5 2 Factory reset Reset Settings 5 2 Slave Mode Standard 5 2 Slave Mode Combiner 5 4 12 DC Out 12V DC ON 5 4 12 DC Out 12V DC OFF 5 4 12 DC Out 12V ON if Fault 5 4 12 DC Out 12V OFF if...

Страница 18: ...iagnostics Menu Structure Main Menu 6 1 Heatsink 40 C 6 Diagnostics 6 1 Heatsink 6 2 Loop A R L 1 635R 123uH 6 3 Loop B R L 1 635R 123uH 6 Diagnostics 6 2 Loop A R L 6 Diagnostics 6 3 Loop B R L 6 Dia...

Страница 19: ...Main Menu 7 Ethernet 7 1 DHCP 7 Ethernet 7 2 MAC Address 7 Ethernet 7 3 IP Address Amplifier re starts Returns to home screen 7 Ethernet 7 4 Set IP Addr 7 Ethernet 7 5 Subnet Mask 7 Ethernet 7 6 Set...

Страница 20: ...rent status items are viewed by navigating the menu using left and right Status Menu Heatsink 45 C Active faults are shown here if present System Error E G 1 Output B Clip System Error E G 2 Power Der...

Страница 21: ...Numerical values can only be adjusted in whole dB steps MLC settings are still adjustable in 0 25dB steps There is no option to adjust custom MLC The test signal continuous tone frequency is not adju...

Страница 22: ...server If an existing Ethernet IP system is available then the driver can be plugged into it and it will configure itself When the driver obtains an IP address it will display it on the front panel L...

Страница 23: ...n Settings Tab The settings tab allows control of the most important settings of the driver The items on this page are sliders and drop down boxes In order that the slider settings cannot be changed b...

Страница 24: ...e value means that more current is driven through loop B dual output Drivers than loop A whilst a negative value means that less current is driven through loop A than loop B Phase Shift This is a drop...

Страница 25: ...cause the driver to lose network connectivity If a connection cannot be obtained after changes re enable DHCP using the front panel controls Enter the new settings below when you press Submit and Res...

Страница 26: ...k when it starts up Submit and Restart Press this button if you have changed any of the network parameters It will save the settings and restart the driver to utilise the new configuration Driver Stat...

Страница 27: ...driver was last restarted or switched on Loop B Parameters The measured value of the resistance and inductance of loop B when the driver was last restarted or switched on Master Slave Status This disp...

Страница 28: ...present on the driver when this Email was sent are listed below 1 Heatsink too Hot Derated 2 Heatsink too Hot Muted The current settings of the driver are listed below Input 1 level is 80 0dB Input 1...

Страница 29: ...o the wireless network to remotely configure the driver If not ask if you can plug a laptop into the network to communicate with the driver 3 If a network is available check whether DHCP is used on it...

Страница 30: ...ternet is not available Check that the wireless connection is still connected to the TP Link Nano Router If all else fails turn off your mobile data so that your device has to use the TP Link Nano Rou...

Страница 31: ...PC you can easily match which driver is which on the DANTE controller If you are installing multiple D Series drivers on the same network it is possible to then change the name to something more appro...

Страница 32: ...s cur Sets the current drive level of the Driver 80 to 0 curo Sets the current offset ve means channel B is quieter than channel A and visa versa 10 to 10 inp1 Set the input 1 gain dB 80 to 0 inp2 Set...

Страница 33: ...Returns loop A inductance as measured at the last power cycle lprb Returns loop B resistance as measured at the last power cycle lplb Returns loop B inductance as measured at the last power cycle temp...

Страница 34: ...orrupted SETTINGS CORRUPT Please contact Ampetronic technical support This error occurs during initial tests before the web interface is available and so is not reported on it You should check each se...

Страница 35: ...op The message is displayed on the front panel for 5 seconds and on the web interface CHANNEL B OPEN CIRCUIT As above for loop B These are information messages and do not indicate an error DIAGNOSTICS...

Страница 36: ...power switch is toggled to the ON I position Check fuse continuity A 20mm fuse is incorporated into the AC POWER inlet It is necessary to remove the power cord before extracting the fuse holder Test t...

Страница 37: ...y with the loop wire over an appreciable distance Loop amplifiers are capable of delivering high currents at audio frequencies If the loop cables are run close to sensitive signal cables it may be pos...

Страница 38: ...s When installing on raised access floors it is advisable to insulate beneath the flat copper tape installation using Ampetronic PWT or similar tape The loop short to earth may only be completed when...

Страница 39: ...nt pink noise 3 3Arms short term peaks 10A per ch D10 X 10Arms 14 1Apk up to 60 seconds continuous 1kHz sine wave peak 14 1A per channel Cont pink noise 4 7Arms short term peaks 14 1A per ch D14 X 14A...

Страница 40: ...ich can be significant Phase Shift User selectable at 0 or 90 between outputs Additional Functions Fault Monitoring Indicators on the front panel Clipping delivering over the rated voltage per channel...

Страница 41: ...plifier is overdriven and attempts to deliver an output voltage or current beyond its maximum capability Clipping will affect frequency response make speech unintelligible to the system user Class D A...

Страница 42: ...ork LAN is a network of computers or network enabled devices that interconnects them within a limited area or building generally via a central network Switch Multiple LANs can be connected via a Route...

Страница 43: ...n the incoming packet and an internal routing table the router determines which port line to send out the packet ports typically connect to Ethernet cables Switch A network switch also called switchin...

Страница 44: ...032 2015 Emission EN55103 2 2009 Immunity Directive 2014 30 EU Safety EN60065 2014 Directive 2011 65 EU RoHS Date October 2016 J R Pieters Managing Director Ampetronic Ltd CAUTION Changes or modificat...

Страница 45: ...INSTALLATION NOTES Ampetronic D Series Installation Handbook User Guide Page 43...

Страница 46: ...INSTALLATION NOTES Ampetronic D Series Installation Handbook User Guide Page 44...

Страница 47: ...INSTALLATION NOTES Ampetronic D Series Installation Handbook User Guide Page 45...

Страница 48: ...Contents Copyright Ampetronic Ltd 2016 All rights reserved UP1 9001 4...

Отзывы: