12. Telnet Commands
Introduction
This document describes the telnet command format and the commands that the Driver recognises .
The Telnet interface of the Driver is on port 9760 . Therefore to make a Telnet connection to an
amplifier whose IP address is 10.2.0.144 the Telnet command would be ‘Telnet 10.2.0.144 9760’.
Command Format
The commands break down into two groups – those that set a value in the Driver and those that
read a value back .
Setting Commands
The command is a string followed by “=” and then the value as specified in the table below.
For example, to set the current to -20dB the command is “cur=-20 ” is sent . The space command
(ASCII character 32) is used to end a command and trigger the interpreter to process the command.
This means that space is never used within a command .
The recognised commands are:
Command
Function
Accepted parameters
cur
Sets the current drive level of the Driver
-80 to 0
curo
Sets the current offset . –ve means channel B is
quieter than channel A and visa versa
-10 to +10
inp1
Set the input 1 gain dB
-80 to 0
inp2
Set the input 2 gain dB
-80 to 0
mlc1
Set the first MLC slope level in dB/Octave
0 .0 to 4 .0
mlcf
Set the MLC mid frequency in Hz
200 to 5000
mlc2
Set the second MLC slope level in dB/Octave
0 .0 to 4 .0
mlcq
Use a pre-set MLC response
0 to 18
tfrq
Set the frequency of the test sine wave in Hz
200 to 5000
tsts
Set the test signal used by the amplifier
“Off”
”Combi10”
“Combi16”
“Combi25”
”Pink”
“Sine”
in1m
Set the input mode of channel 1 – send a number
corresponding to the required input mode
0 = “line”
1 = “mic no phantom”
2 = “mic with phantom”
in2m
Set the input mode of channel 1 – send a number
corresponding to the required input mode
0 = “line”
1 = “mic no phantom”
2 = “mic with phantom”
3 = “AES digital input”
4 = “DANTE” (if fitted)
phse
Sets the phase shift mode
0 = “no phase shift”
1 = “channel B shifted by 90”
pwlc
Controls Emails on power cycling
“true” enables,
“false” disables
erlc
Controls Emails on error conditions
“true” enables
“false” disables
Содержание d series
Страница 1: ...D Series Installation Handbook User Guide www ampetronic co...
Страница 2: ......
Страница 45: ...INSTALLATION NOTES Ampetronic D Series Installation Handbook User Guide Page 43...
Страница 46: ...INSTALLATION NOTES Ampetronic D Series Installation Handbook User Guide Page 44...
Страница 47: ...INSTALLATION NOTES Ampetronic D Series Installation Handbook User Guide Page 45...
Страница 48: ...Contents Copyright Ampetronic Ltd 2016 All rights reserved UP1 9001 4...