Orange Red
Red
Red
Red
Red
Red
1 s
0,5 s
0,5 s
0,5 s
0,5 s
0,5 s
1 s
0,5 s
0,5 s
0,5 s
0,5 s
0,5 s
0,5 s
2 s later
S-4001 ISBH+I SM 30°
2-5
Revised: 10/2017
E-mail: [email protected]; webside: www.amfreece.com
Phone: +420 582 309 146; Fax: +420 582 360 606
TROUBLESHOOTING
4. ERROR MESSAGES OF THE SERVO
The following messages can be seen on the servo, which is placed inside the control box. In order to eliminate these
messages, switch off the machine for 1 minute. Then switch the machine on again. The error message should not
appear on the display. If the message appears - call AMF Reece service.
PWR
- Power supply indication:
INDICATOR
STATUS
Lit green
Voltage is good
Lit orange - Flashes at a 1
sec. intervals
Varning - i.e.:
- Exceeded power
- Exceeded feed back
- Default of inner fan
Lit red
Alarm - default
Alarm indicator on the Servo Drive
The alarm LED indicator on the front of the Servo Drive lights up if an error is detected. The indicator shows the alarm
code by the number of orange and red flashes.
Example:
When an overload alarm (alarm code 16) has occurred and the Unit has stopped the indicator will flash in orange
and 6 times in red.
Orange 10s digit, Red: 1s digit
C
N
1
C
N
2
C
N
A
C
N
B
C
N
3
PWR
ALM
Power
supply
indicator
Alarm
indicator
(ALM)
ALM
- Default indication (Alarm indicator):
in case default appears, the indicator is switched on.