C - CORRECT USAGE
1-13
2. NEEDLE INSTALLATION
WARNING!
Before performing this adjustment, switch the main machine power off to prevent accidental starting of
the machine. Disconnect the air supply and dissipate any stored energy.
Use needles ordering number 02.0750.2.110 (750SC 90/14) only - see accessories.
It is also possible to use needles ordering number 02.0750.2.100 (750 SC 80/12),02.0750.2.109 (750 SC 70/10) for
sewing the thin materials - these needles are not included in the standard machine equipment.
1. Using the screwdriver push the latch
1
and open the needle bar cover
2
.
Note:
The accessories contain the lever
5
(ordering number 22.0213.0.000) and screw
(ordering number 08.6000.4.005) with washer
(08.6850.4.000)
6
, which is possible to fit to
the latch. It allows opening of the cover
without using the tool.
2. Loosen the screw
3
and remove the
needle.
3. Insert the new needle so that the long thread
groove
4
is in the rear and the spot for the
clamping screw
3
is in line. Do not install a
bent or broken needle. Roll the needle on a flat
surface to check for straightness.
4. Tighten the screw
3