1-53
S-4001 ISBH+I SM 30°
Released: 09/2017
E-mail: [email protected]; webside: amfreece.com
Phone: +420 582 309 146; Fax: +420 582 360 606
E - STANDARD MACHINE ADJUSTMENT
17. ADJUSTMENT OF THE STOPPING SENSOR POSITION
Follow the below described steps to set the position of the sensor.
1. Put machine in the service mode (see E-3).
2. Turn the handwheel counter clockwise until the machine is in the position for sewing the second bar. The stop
disk finger
1
must be perpendicular to the sensor
2
.
3. Loosen the screws
3
and move the sensor bracket
4
to the right. Tighten the screws
3
.
4. Loosen M3 screw
5
and adjust the sensor position so that the stop disk finger
1
is in the center of the
sensor mark
6
. The red LED
7
lights up on the sensor.
5. Tighten the M3 screw
5
.
6. Return the machine head back to the working positon.
7. Push the
key on the control panel and switch the machine to the working mode.
8. Start the machine and check the correct stopping of the machine. The needle bar must stop in the home
(upper) position.