1-37
S-4001 ISBH+I SM 30°
Released: 09/2017
E-mail: [email protected]; webside: amfreece.com
Phone: +420 582 309 146; Fax: +420 582 360 606
E - STANDARD MACHINE ADJUSTMENT
8.1. As the Indexer unit needs to be synchronized with the sewing head, it is necessary to set the mechanically
adjusted stitch density in the Indexer parameters on the machine touch-screen panel.
a) Switch the machine to service mode – refer to the section E3
b) Insert a piece of paper under the clamp-feet and rotate the hand-wheel
c) Take the paper out and measure the stitch spacing
x
d) Return to the main screen and set the measured spacing on the following screen:
NOTICE
:
In case you don’t do this adjustment properly, the Indexer clamp-feet will not be synchronized with the sewing head
clamp-feet and they will rotate unintentionally during sewing!