S-4000 BH Omron
1-25
Released 05/2010
e-mail: [email protected]; [email protected]; website: www.amfreece.com
Phone: +420 582 309 286; Fax: +420 582 360 606
D - MACHINE CONTROLS
5 . T E S T S
WARNING! ONLY PROFESSIONAL SERVICE TECHNICIANS SHOULD PERFORM THESE TESTS!
NOTICE! BEFORE PERFORMING ANY TESTS DISMOUNT THE CUTTING KNIFE AND THE
NEEDLE!
The main screen appears on the display. Press
,
appears on the display.
To enter the tests menu, press
key. The following screen appears on the display
Intput tests
Off
Low air pres
. To scroll this menu down, press
key, to scroll this menu up, press
key.
INPUTS TESTS
1.
Intput tests
Off
Low air press
-
If the air pressure falls below 0,5 MPa,
appears
on the display.
Sensor BQ2 is tested by this parameter.
2.
Home sensor
Voltage Rly
Off
Off
-
the end position sensor. Activate the sensor using a metal tool.
Home sensor
Vo l t a g e R l y
O n
O f f
appears on the display.
Switch BQ1 is tested by this parameter.
3.
-
This input signifies when the overvoltage relay is installed. If the voltage
drops below185 V,
Home sensor
Vo l t a g e R l y
O f f
O n
appears on the display. Relay
VC1 tested by this parameter.
4.
-
After pressing the pedal to the first position,
Pedal 1 step
Pedal 2 step
Off
On
appears on the display. Switch SB4 is tested by this parameter.
5.
Pedal 1 step
Pedal 2 step
Off
Off
-
After pressing the pedal to the second position,
Pedal 1 step
Pedal 2 step
On
On
appears on the display. Switch SB5 is tested by this parameter.
6.
Em stop
Clamp button
On
Off
-
After pressing the button
this appears on the display:
Em stop
Clamp Button
Off
Off
. After releasing the button
Em stop
Clamp button
On
Off
appears. Switch SA1 is tested by this parameter.