2-2
DECO 2000
Released 06/2010
e-mail: [email protected]; [email protected]; website: www.amfreece.com
Phone: +420 582 309 286; Fax: + 420 582 360 606
Warning! Inspect the machine on a regular basis and use only quality parts. The manufacturer
recommends using original AMF Reece parts, especially needles, loopers, and throat plates.
The Deco 2000 electronically displays error massages, when worn or damaged parts are detected. If
machine problems occur and the error is not displayed, ensure correct needle installation and thread-
ing. The other troubles are eliminated according to the detailed descriptions listed.
2 . A D J U S T M E N T S Q U I C K R E F E R E N C E L I S T
N O T E : Required machine settings are variable according to the fabric and thread variation used.
The type of thread and fabric will affect the amount of wear on the machine parts.
To obtain the highest quality of the sewing work maintain the following values:
The distance between the upper needle bar and the threat plate 14.3 mm.
The clearance between the lip of lower needle bar and lip on the upper needle bar 23,8 mm.
Needle clearance 0,4 to 1,2 mm.
The clearance between the needle and the end of the pads on the gripper fingers 0,13 mm.
The clearance between the fingers lever and pivot bracket must be 0,4 mm but when the fingers
are closed only.
Keep the clearance between the thread guide and the side of the needle 0,8 mm.
The loopers can not catch the thread separator.
The lifter hook can not catch the looper.
The clearance of the forward end of the slot from the needle eye 0,08 to 0,13 mm.
The clearance between the feed dog above the throat plate 0,4 - 0,8 mm.
The clearance of the needle bar to the dwell position 0,8 to 0,4 mm.
The clearance of the left looper tip from the center of the needle 4,8 mm.
Clearance between the left looper and the needle 0,4 to 0,8 mm.
Clearance from the right looper to the upper needle bar 1,6 to 0,8 mm.
The clearance of right looper to the 0,8 ahead of the left looper.
The clearance between the lower looper tip and before the needle 12,7 mm.
The tip of the hook 0,8 below the top of the edge of the gripper fingers.
The bender plate clearance to the needle 0,4 mm.
Gap between the sensor face and flag on cam 0,254 mm.
The gap between feed dog sensor and flag assembly 8 mm.
TROUBLESHOOTING
1 . I N T R O D U C T I O N