Electrical Specifications
TM-F2OP-C1XN-01
A-5
Temperature Coefficient:
h
Voltage (0.02% of Vmax/°C)
Current (0.03% of Imax/°C)
For Resistive Programming:
Voltage (0.06% of Vmax/°C)
Current (0.06% of Imax/°C)
12 mV
13.8 mA
36 mV
28 mA
20 mV
8.4 mA
60 mV
16.8 mA
30 mV
5.4 mA
90 mV
10.8 mA
60 mV
2.7 mA
180 mV
5.4 mA
120 mV
1.2 mA
360 mV
2.4 mA
OVP Adjustment Range:
(5% to 110% of Vmax)
3-66 V
5-110 V
7.5-165 V
15-330 V
30-660 V
Efficiency:
i
0.90
0.90
0.90
0.91
0.91
a.
Minimum output voltage is <0.15% of rated voltage at zero output setting.
b.
Minimum output current is <0.5% of rated current at zero output setting when measured at minimum 10% of full power
load.
c.
For input voltage variation over the AC input voltage range, with constant rated load.
d.
For 0-100% load variation, with constant nominal line voltage.
e.
Current mode noise is measured from 10% to 100% of rated output voltage, full current.
f.
Maximum drift over 30 minutes with constant line, load, and temperature, after power on.
g.
Maximum drift over 8 hours with constant line, load, and temperature, after 30-minute warm-up.
h.
Change in output per
°
C change in ambient temperature, with constant line and load.
i.
Typical efficiency at nominal input voltage and full output power.
Table A-2
Specifications for 60 V to 600 V Models
Models
60-46
100-28
150-18
300-9
600-4
Содержание Sorensen XFR 100-28
Страница 3: ...This page intentionally left blank ii...
Страница 5: ...This page intentionally left blank iv...
Страница 7: ...This page intentionally left blank vi...
Страница 13: ...xii...
Страница 15: ...xiv...
Страница 25: ...1 10...
Страница 67: ...3 18...
Страница 73: ...Remote Operation 4 6 TM F2OP C1XN 01 Figure 4 1 Connecting Programming Sources to J2 Connector...
Страница 75: ...4 8...
Страница 87: ...5 12...