Specifications
A-4
TM-F2OP-C1XN-01
Table A-2
Specifications for 60 V to 600 V Models
Models
60-46
100-28
150-18
300-9
600-4
Output Ratings:
Output Voltage
a
Output Current
b
Output Power
0-60 V
0-46 A
2760 W
0-100 V
0-28 A
2800 W
0-150 V
0-18 A
2700 W
0-300 V
0-9 A
2700 W
0-600 V
0-4 A
2400 W
Line Regulation:
c
Voltage
(0.01% of Vmax +
2 mV)
Current (0.01% of Imax + 2 mA)
8 mV
6.6 mA
12 mV
4.8 mA
1 7mV
3.8 mA
32 mV
2.9 mA
62 mV
2.4 mA
Load Regulation:
d
Voltage (0.02% of Vmax +
5 mV)
Current (0.02% of Imax + 5 mA)
17 mV
14.2 mA
27 mV
10.6 mA
35 mV
8.6 mA
65 mV
6.8 mA
125 mV
5.8 mA
Meter Accuracy:
Voltage (1% of Vmax + 1 count)
Current (1% of Imax + 1 count)
0.7 V
0.56 A
1.1 V
0.38 A
1.6 V
0.19 A
4 V
0.1 A
7 V
0.05 A
Output Noise (0-20 MHz):
Voltage (p-p)
150 mV
175 mV
200 mV
400 mV
500 mV
Output Ripple (rms):
Voltage
Current
e
15 mV
100 mA
25 mV
80 mA
25 mV
40 mA
40 mV
20 mA
100 mV
10 mA
Drift (30 minutes):
f
Voltage (0.05% of Vmax)
Current (0.7% of Imax)
For Resistive Programming:
Voltage (0.6% of Vmax)
Current (0.6% of Imax)
30 mV
322 mA
360 mV
276 mA
50m V
196m A
600 mV
168 mA
75 mV
126 mA
900 mV
108 mA
150 mV
63 mA
1800 mV
54 mA
300 mV
28 mA
3600 mV
24 mA
Drift (8 hours):
g
Voltage (0.05% of Vmax)
Current (0.05% of Imax)
For Resistive Programming:
Voltage (0.3% of Vmax)
Current (0.3% of Imax)
30 mV
23 mA
180 mV
138 mA
50 mV
14 mA
300 mV
84 mA
75 mV
9 mA
450 mV
54 mA
150 mV
4.5 mA
900 mV
27 mA
300 mV
2 mA
1800 mV
12 mA
Содержание Sorensen XFR 100-28
Страница 3: ...This page intentionally left blank ii...
Страница 5: ...This page intentionally left blank iv...
Страница 7: ...This page intentionally left blank vi...
Страница 13: ...xii...
Страница 15: ...xiv...
Страница 25: ...1 10...
Страница 67: ...3 18...
Страница 73: ...Remote Operation 4 6 TM F2OP C1XN 01 Figure 4 1 Connecting Programming Sources to J2 Connector...
Страница 75: ...4 8...
Страница 87: ...5 12...