Features and Specifications
1-6
TM-F2OP-C1XN-01
Rear Panel SW1 Switch
The SW1 Programming, Monitoring, and Shutdown Select switch is an
8-position piano DIP switch located on the power supply’s rear panel. See
Figure 1-3. The SW1 switch enables you to choose:
•
Resistive programming of output voltage or current limit
•
Output voltage and current limit programming scales
•
Output voltage and current monitor scales
•
Remote shutdown circuit logic
•
Over temperature shutdown mode
Table 1-2 shows the functions assigned to each SW1 switch.
Figure 1-3
Programming and Monitoring SW1 Switch
(Switch is shown in factory default configuration.)
1
Resistive Programming of Output Voltage
2
Resistive Programming of Output Current
3
Selects Output Voltage Programming Source Range
4
Selects Output Current Limit Programming Source Range
5
Selects Output Voltage Monitor Range
6
Selects Output Current Monitor Range
7
Selects Remote Shutdown Logic
8
Selects Over Temperature Shutdown Reset Mode
Table 1-2
Rear Panel SW1 Switch Assignments
Switch
Function
Open
a
a. Factory defaults underlined.
Closed
SW1-1
1 mA current source for resistive programming
of output voltage
Voltage source
programming
Resistive programming
(0-5 k, 0-10 k)
SW1-2
1 mA current source for resistive programming
of output current limit
Voltage source
programming
Resistive programming
(0-5 k, 0-10 k)
SW1-3
Output voltage programming source range select 0-5 V (0-5 k)
0-10 V (0-10 k)
SW1-4
Output current limit programming source range
select
0-5 V (0-5 k)
0-10 V (0-10 k)
SW1-5
Output voltage monitor range select
0-5 V
0-10 V
SW1-6
Output current monitor range select
0-5 V
0-10 V
SW1-7
Remote shutdown logic select
HIGH=OFF
HIGH=ON
SW1-8
Over temperature shutdown reset mode select
Auto reset
Latch OFF
Содержание Sorensen XFR 100-28
Страница 3: ...This page intentionally left blank ii...
Страница 5: ...This page intentionally left blank iv...
Страница 7: ...This page intentionally left blank vi...
Страница 13: ...xii...
Страница 15: ...xiv...
Страница 25: ...1 10...
Страница 67: ...3 18...
Страница 73: ...Remote Operation 4 6 TM F2OP C1XN 01 Figure 4 1 Connecting Programming Sources to J2 Connector...
Страница 75: ...4 8...
Страница 87: ...5 12...