iv

3050-AP Moisture Analyzer

WARRANTY AND CLAIMS

We warrant that any equipment of our own manufacture or manufactured for us pursuant to our 

specifications which shall not be, at the time of shipment thereof by or for us, free from defects in mate-

rial or workmanship under normal use and service will be repaired or replaced (at our option) by us 

free of charge, provided that written notice of such defect is received by us within twelve (12) months 

from date of shipment of portable analyzers or within eighteen (18) months from date of shipment or 

twelve (12) months from date of installation of permanent equipment, whichever period is shorter. All 

equipment requiring repair or replacement under the warranty shall be returned to us at our factory, 

or at such other location as we may designate, transportation prepaid. Such returned equipment shall 

be examined by us and if it is found to be defective as a result of defective materials or workmanship, 

it shall be repaired or replaced as aforesaid. Our obligation does not include the cost of furnishing any 

labor in connection with the installation of such repaired or replaced equipment or parts thereof, nor 

does it include the responsibility or cost of transportation. In addition, instead of repairing or replacing 

the equipment returned to us as aforesaid, we may, at our option, take back the defective equipment, 

and refund in full settlement the purchase price thereof paid by Buyer. 

Process photometric analyzers, process moisture analyzers, and sampling systems are warranted to 

perform the intended measurement, only in the event that the customer has supplied, and AMETEK 

has accepted, valid sample stream composition data, process conditions, and electrical area classification 

prior to order acknowledgment.  The photometric light sources are warranted for ninety (90) days from 

date of shipment.  Resale items warranty is limited to the transferable portion of the original equipment 

manufacturer’s warranty to AMETEK.   If you are returning equipment from outside the United States, 

a statement should appear on the documentation accompanying the equipment being returned declar-

ing that the goods being returned for repair are American goods, the name of the firm who purchased 

the goods, and the shipment date.

The warranty shall not apply to any equipment (or part thereof) which has been tampered with or 

altered after leaving our control or which has been replaced by anyone except us, or which has been 

subject to misuse, neglect, abuse or improper use. Misuse or abuse of the equipment, or any part thereof, 

shall be construed to include, but shall not be limited to, damage by negligence, accident, fire or force 

of the elements. Improper use or misapplications shall be construed to include improper or inadequate 

protection against shock, vibration, high or low temperature, overpressure, excess voltage and the like, 

or operating the equipment with or in a corrosive, explosive or combustible medium, unless the equip-

ment is specifically designed for such service, or exposure to any other service or environment of greater 

severity than that for which the equipment was designed.

The warranty does not apply to used or secondhand equipment nor extend to anyone other than the 

original purchaser from us.

THIS WARRANTY IS GIVEN AND ACCEPTED IN LIEU OF ALL OTHER WARRANTIES, WHETHER 

EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION AND WARRANTIES OF FITNESS OR 

OF MERCHANTABILITY OTHER THAN AS EXPRESSLY SET FORTH HEREIN, AND OF ALL OTHER 

OBLIGATIONS OR LIABILITIES ON OUR PART. IN NO EVENT SHALL WE BE LIABLE UNDER THIS 

WARRANTY OR ANY OTHER PROVISION OF THIS AGREEMENT FOR ANY ANTICIPATED OR 

LOST PROFITS, INCIDENTAL DAMAGES, CONSEQUENTIAL DAMAGES, TIME CHANGES OR ANY 

OTHER LOSSES INCURRED BY THE ORIGINAL PURCHASER OR ANY THIRD PARTY IN CONNEC-

TION WITH THE PURCHASE, INSTALLATION, REPAIR OR OPERATION OF EQUIPMENT, OR ANY 

PART THEREOF COVERED BY THIS WARRANTY OR OTHERWISE. WE MAKE NO WARRANTY, 

EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION ANY WARRANTIES OF FITNESS OR 

OF MERCHANTABILITY, AS TO ANY OTHER MANUFACTURER’S EQUIPMENT, WHETHER SOLD 

SEPARATELY OR IN CONJUNCTION WITH EQUIPMENT OF OUR MANUFACTURE. WE DO NOT 

AUTHORIZE ANY REPRESENTATIVE OR OTHER PERSON TO ASSUME FOR US ANY LIABILITY IN 
CONNECTION WITH EQUIPMENT, OR ANY PART THEREOF, COVERED BY THIS WARRANTY.

Содержание 3050-AP

Страница 1: ...Model 3050 AP Moisture Analyzer User Manual Process Instruments 455 Corporate Boulevard Newark DE 19702 PN 305562901 Rev G Configurator Software Version 1 73...

Страница 2: ...i Tel 86 21 6426 8111 Fax 86 21 6426 7818 FRANCE Tel 33 1 30 68 89 20 Fax 33 1 30 68 89 29 GERMANY Tel 49 21 59 91 36 0 Fax 49 21 59 91 3639 MIDDLE EAST Dubai Tel 971 4 881 2052 Fax 971 4 881 2053 SIN...

Страница 3: ...of practical experience working with customers John became the committed product champion of the Quartz Crystal Microbalance method of moisture measurement He constantly provided ideas on application...

Страница 4: ...r on the documentation accompanying the equipment being returned declar ing that the goods being returned for repair are American goods the name of the firm who purchased the goods and the shipment da...

Страница 5: ...Requirements 2 1 Power Requirements 2 1 System Tubing 2 1 Dry Reference Gas 2 1 Sample Gases 2 1 Sample pressure and temperature requirements 2 2 Mechanical Installation 2 5 Dryer Installation 2 6 El...

Страница 6: ...ILURE TO FOLLOW THE INSTALLATION AND START UP INSTRUCTIONS MAY VOID THE IN STRUMENT WARRANTY Read and adhere to this warning when explosion proof housing is in use WARNING Before removing cover turn o...

Страница 7: ...r is a technique allowing high frequency shield bonding while avoiding the AC ground metal connection In the case of shielded cables the drain wire or braid connection must be kept short A two inch co...

Страница 8: ...ipment is suitable for use in non hazardous areas only If the 3050 AP is to be powered by a source of 24 Vdc other than that supplied by AMETEK the power source s output must be isolated from hazardou...

Страница 9: ...nvironment and to conserve our natural resources AMETEK recommends that you arrange to recycle this product when it reaches its end of life Waste Electrical and Electronic Equipment WEEE should never...

Страница 10: ...x 3050 AP Moisture Analyzer This page intentionally left blank...

Страница 11: ...uartz crystal has been coated with a proprietary hygroscopic coating This coating selectively and reversibly absorbs moisture from a sample gas stream As the crystal is exposed to a gas stream contain...

Страница 12: ...difference are stored in an EE PROM within the QCM sensor module Controller Communication All analyzer functions are controlled by a microprocessor housed within the smart sensor Communication with th...

Страница 13: ...4 2001 AM ETEK has provided a means of using either method in the 3050 OLV product Specifically in the gas list we have cited two separate entries for natural gas The first entry is labeled Natural Ga...

Страница 14: ...RS 485 two and four wire mode Alarm Contacts Concentration Alarm Data Valid System Alarm Hermetically sealed reed type 30 Vac max 60 Vdc max 10 VA max Resistive Limit of Detection 0 1 ppmv when used w...

Страница 15: ...Power Requirements Analyzer 24 Vdc 50 watts Analyzer Environmental Conditions Ambient Temperature Analyzer 5 C to 50 C Relative humidity up to 90 noncondensing Pollution Degree 2 Maximum altitude 200...

Страница 16: ...g gases have been tested for chemical compatibility with the seals and gaskets used in this instrument air nitrogen oxygen helium neon argon krypton xenon Freon 12 Freon 114 Freon 116 Sulfur Hexafluor...

Страница 17: ...be isolated from hazardous mains voltages by use of double or reinforced insultation having a minimum dielectric strength of 2300 Vac System Tubing Recommended system tubing is 1 8 inch OD 316 stainle...

Страница 18: ...will also increase the response time of the system This increase in response time is caused by the large surface area of the filter element If you have questions concerning the sampling requirements...

Страница 19: ...Instalation and Startup 2 3 Figure 2 1 Model 3050 AP front and side view...

Страница 20: ...2 4 3050 AP Moisture Analyzer Figure 2 2 Model 3050 AP rear view...

Страница 21: ...nec tion instructions and figure 2 4 3 Connect the exhaust fitting to appropriate vent system Leave exhaust out fitting capped or blocked with an isolation valve until sample gas is flowing This preve...

Страница 22: ...bes through female compression nuts and ferrules until they bottom out f Using two 7 16 inch wrenches one to hold the bulkhead fitting swage the compression fittings into the bulkhead fittings on the...

Страница 23: ...to figure 2 5 and figure 2 6 3 Connect RS 232 or RS 485 serial communication from analyzer to the PC being used for customer parameter setup Refer to figures 2 7 through 2 9 4 Insert the RS 485 termi...

Страница 24: ...2 8 3050 AP Moisture Analyzer Figure 2 5 3050 AP Power and Signal Connections...

Страница 25: ...Instalation and Startup 2 9 Figure 2 6 4 20 mA Output Wiring...

Страница 26: ...2 10 3050 AP Moisture Analyzer Figure 2 7 RS 232 Wiring...

Страница 27: ...Instalation and Startup 2 11 Figure 2 8 RS 485 Cables Multiple 3050 OLV s...

Страница 28: ...2 12 3050 AP Moisture Analyzer Figure 2 9 RS 485 to RS 232 Conversion for host PC...

Страница 29: ...s power is supplied to the system The red LED is used to reflect the status of the concentration data valid and system alarms In the event of a concentration alarm the red LED will be on The yellow LE...

Страница 30: ...nvalid Signal Oven temperature is out of tolerance Analyzer detected problem with reference gas NOTE Data valid contact opens on all alarms and stays closed during normal functions and readings An ope...

Страница 31: ...6 color display Configurator Software Installation 1 Insert the Setup Disk 1 in your floppy disk drive 2 Choose RUN from the Windows Start Menu 3 Type the drive letter followed by a colon and a backsl...

Страница 32: ...Restores analyzer internal parameters from a file The open dialog box will appear so that you can open the file This but ton may be used for emergency recovery Live Data Not Checked System uses demons...

Страница 33: ...tup button to setup PC communications Port Select the COM port on the computer used to connect to your device Baud Rate Select the baud rate at which data will be transferred Either 9 600 or 19 200 RS...

Страница 34: ...ifies the analyzer s address and what type of serial com munication cable is being used Address Type the network address for the device being connected Two wire RS 485 Click if device is using two wir...

Страница 35: ...unit of measure for data output All values entered must be the same unit of measure as selected Process Pressure Used when dewpoint C or dewpoint F is selected as unit of mea sure Units List box allow...

Страница 36: ...Check to activate alarm High limit Enter high limit value Low limit Enter low limit value 4 Define Dryer and Clock Settings using the Verify Tab Refer to figure 3 5 Dryer Production Code Enter dryer...

Страница 37: ...3 7 Parameter Setup Figure 3 7 AMETEK 3050 AP Configurator Dryer Production Code Adjust Span Figure 3 6 AMETEK 3050 AP Configurator Set Clock Figure 3 5 AMETEK 3050 AP Configurator Verification Tab...

Страница 38: ...s connection status It displays whether the analyzer is on line off line or in demo mode Lower left list box Displays system conditions and alarms List Examples Verification Pending Flow Error Replace...

Страница 39: ...read resistance Refer to figure 2 5 for location of contacts on analyzer Opened contacts should read infinity Closed contacts should read zero The Test mA Output push buttons allow you to test the an...

Страница 40: ...me in the Save As dialog and press Save button The file format is csv which is Excel compatible All data displayed on the Monitor page will be stored in the specified file Off Data collection will ter...

Страница 41: ...lacement Parts AMETEK Part Description Part Number Sensor Assembly 305 122 901S CO2 Calibrated Sensor Assembly 305 122 903S Dryer 305 400 901S User Manual 305 562 901 MCU Board 305 110 908S Interface...

Страница 42: ...be the responsibility of the customer WARRANTY EXTENSIONS AMETEK offers a 2 or 3 year warranty extension for your analyzers The warranty is identical to the original policy supplied with the analyzer...

Страница 43: ...odel 3050 AP Moisture Analyzer Configurator Software A Windows based graphical user interface that provides a means for communicating with a single Model 3050 AP Moisture Analyzer Contaminates Liquids...

Страница 44: ...al representation of a vertical panel meter on which 3050 AP analyzer results are displayed PC Personal computer Port The specific COM serial port of a host PC that will be used for RS 232 serial comm...

Страница 45: ...ch the analyzer timing is configured such that the reference gas is flowing for a greater portion of time than the sample gas This helps to prolong the life of the QCM sensor SLPM Standard liters per...

Страница 46: ...5 4 3050 AP Moisture Analyzer This page intentionally left blank...

Отзывы: