Fixed Spot Thermometers
SPOT Actuator
Positional Points:
900 points over 90 degrees
Speed:
Adjustable between approximately 25 ° and
100 ° swivel per second
Sealing: IP65
Power Requirement:
Power over Ethernet 802.3 at (PoE+) or 18 to
36 V DC 30 W
Mounting:
4 holes Dia. 8.5. 109 x 70 pitch
Ambient Temperature Range: 5 to 60 °C / 41 to 140 °F
Inputs:
Modbus TCP or 24 V Digital I/O
Ethernet, 4 pin M12
Outputs:
Modbus TCP for full scan details; 24 V Digital
and 4 to 20 mA signals for simple control
Ethernet, 4 pin M12
Rotation Clearance:
400 mm Diameter
Settings:
Scan range, hotspot location or billet scan,
remote or automatic triggering and speed, site
orientation, network and display configuration
Remote:
Optional, available with 2 m, 5 m or 10 m cable
Configurations:
Analogue Only (1 cable):
PLC triggers scan
with 24 V digital signal and reads 4 to 20 mA
temperature from SPOT
Analogue and Optional Remote:
As above,
also local control
Ethernet or Webserver (1 cable):
Connect
to the Actuator for access to both SPOT and
Actuator on separate IP addresses, ability to
configure all settings, trigger a scan and read
scan data using Modbus TCP or Webserver
Ethernet and Optional Remote:
As above,
also local control
SPECIFICATION
6
User Guide
6 - 0
Содержание SPOT ACTUATOR