Installation Guide
Thermal Imaging System
NIR-B Borescope
Electrical Auto Retract
The front and back position switch trigger points can
also be finely adjusted using the fine adjustment
screws on the main carriage of the retract system
(Fig. 6-2).
Once adjusted, tighten the screws to 5 Nm.
Refer to Section 9.
SYSTEM
ADJUSTMENT AND
ALIGNMENT TO PROCESS
6
The system camera can be aligned to the port left to
right by either moving the position of the front and
rear bracket along the bolt slots or via the adjustable
clamp base (Sheet 9 of the Installation Drawings).
The camera can be adjusted forward and backward
by using the 2 x M10 bolts or adjusting its position in
the quick release clamp as shown on Sheet 9 of the
Installation Drawings.
If required, the front position switch (Fig. 6-1) can be
moved easily by loosening the 2 x M5 Cap head bolts
and sliding into the required position along the linear
slide assembly. The rear switch can be adjusted in
the same manner if required.
Adjust/replace cable ties as necessary.
Once adjusted, tighten the bolts to 6 Nm.
Fig. 6-1
Fig. 6-2
6 - 0
6 Nm
5 Nm