Selecting a value
A cursor below a text or numerical value shows what is affected by
the dial. To increase the value, turn the dial clockwise. To decrease
the value, turn the dial counter-clockwise. The value can be reset by
turning the dial several clicks counter-clockwise.
To simplify entering large numerical values, the cursor moves up to
the next digit if the dial is turned quickly in one direction. The
cursor moves back one place to the right every two seconds if the
dial is not turned. The text or numerical value displayed is accepted
by pressing
OK
. To cancel, press
ESC
.
3.3
Menu overview
Work mode changing menu. From here the pump is started,
stopped, held, paused and continued. This menu is accessed from all
positions by turning the dial one click counter-clockwise. The
appearance of this menu depends on the current mode.
Main operating menu. The menu is accessed from all positions by
pressing
ESC
repeatedly.
Setting flow rate in ml/min.
Setting concentration and gradient values.
Wash program selection. Individual pump cylinder assemblies or
a complete pump wash can be selected.
Pump synchronisation selection. This means that the pump
cylinder(s) are run to one stop position. Individual pump cylinder
assemblies or a complete pump synchronisation can be selected.
Change piston direction selection. Individual piston direction or
both piston directions can be selected.
Check internal operating values. See Reference information section
B.1.
Setup language, pressure limits and unit, etc. See Reference
information section B.2.
Set different timer options. The pump can be started or stopped at
set times. See Reference information section B.3.
Alarm/Timer 12:30:52
Setup
Check
Change Direction
Pump Sync 20ml/min
Pump Wash 20ml/min
Set Conc./Gradient
(0.0%B)
Set Flow Rate
(0.00ml/min)
Run 13.40ml/min
2.00MPa 45.5%B
End 1.00ml/min
Run
Pump P-920
User Manual 18-1125-54 Edition AB
10
3
Operation
Setup Hi Press Limit
(5.00MPa) 5.00
Parameter
Current value
New value to be set
18-1125-54_ab.qxd 1998-10-22 12:49 Sida 10 (1,1)