C. SET UPPER AND LOWER TRAVEL LIMITS
Step 1:
Test the lower travel limit by operating the lift downward, keeping the switch
depressed. The unit should begin to decelerate about 3
"
from its final resting position and
stop clear of the floor.
Step 2: The final stopped position can be adjusted to accommodate the height of the user
by repositioning the limit cam located in a slot in the rail.
Step 3:
Use a
5
/
64
"
Allen wrench to loosen the set screw in the limit cam. Adjust the limit
cam up or down and retighten the set screws. Repeat the above Steps until the lift stops in
the desired position.
Step 4:
Repeat the above Steps to set the upper limits. For safety, the footrest should be
set at least level with the upper landing.
Step 5: The optimum position is met when the seat height above the floor is the same at
the top and bottom of the stairs.
D. TEST SAFETY STOP SWITCHES
Step 1:
Safety stop switches are located in both the upward and downward ends of the
chassis providing protection from obstructions on the rail.
Step 2:
Safety stop switches are located in the footrest bottom pan providing protection
from obstructions and trapping hazards on the stairs.
Step 3:
Safety stop switch is part of the swivel seat mechanism and prevents the lift from
operating when the swivel is in use.
Step 4:
Test all the safety stop switches by driving the lift down and touching the
downward end of the chassis, the lower edge of the footrest, and the underside of the
footrest in both its folded and unfolded positions.
Step 5:
In each of the above cases the unit should come to an immediate halt. The LED
indicator light on the armrest control should turn to orange and the unit should beep
intermittently.
Step 6:
When the control switch is released, the unit should NOT be able to be driven in the
direction that the lift initially engaged the obstacle. Test this condition.
Step 7:
Test to ensure that the lift can only be driven away from the obstruction. The LED
indicator light will turn to green and stop beeping indicating a safe operating condition.
Step 8:
Repeat the above tests while driving the lift in opposite direction.
Step 9:
If any safety condition does not function properly, carefully review all installation
instructions, reset the “ON /OFF” switch and check that the LED indicator light is green.
Repeat the above tests.
Step 10:
If any safety stop switch fails to immediately stop the lift and/or a red LED
indicator light appears, remove the key to prevent further use of the lift and immediately
call the manufacturer for assistance in diagnosing and repairing the problem.