15 //
28
Rave Stair Lift Manual | www.Ameriglide.com | 866-378-6648
20419 P/N: 630-00078 Rev E
E. ADDITIONAL SYSTEM CHECKS
Step 1:
After the successful testing of all safety switches, sit on the lift and operate to
the top of the stairs. Keeping the control switch depressed continuously, the lift should
gently decelerate and then stop at the top of the track.
Step 2: As a final adjustment, sit on the lift and do two (2) complete up trips and stop
with the chair at the bottom. Then tighten the compression screw in the top end plate,
then run the chair to the top and again tighten the compression screw. Run the chair to
the middle and do a final tightening of the compression screw.
Step 3:
Drive the lift to the bottom, keeping the control switch depressed all the time,
and check that the lift gently decelerates and stops so the footrest pan is clear of the
floor. If necessary adjust the limit cams with a
5
/
64
"
Allen wrench.
Step 4: Move the lift about three (3) feet from either the top or bottom of the rail. After
30 seconds the armrest LED indicator light will show orange and beep indicating that
the lift is not positioned on a charge point. The beep will stop after 30 seconds, but the
armrest LED indicator light will continue to flash orange.
Step 5:
Test the seat swivel at the top by using the levers and swiveling the seat towards
the landing and stop the seat at 35
°
and 85
°
. The seat swivel levers will release into a
locked position at each of these angles. The lift will not operate in any of these positions
if the control switch is depressed, and the LED indicator light will turn orange. Return the
seat to its normal position and the LED indicator light will turn green and the lift will now
operate normally.
Step 6:
Drive to the top or bottom and check the battery charging light. If the light is
orange or red, the batteries are being charged.
THE LIFT IS NOW
READY TO USE!
Содержание RAVE