The following technical specifications cover the MicroMax interrupters. For additional specifications
on load current, refer to
Specification
GPS300
GPS350
GPS360
Input Power
10-60V DC or 8-42V
AC
10-60V DC or 8-42V
AC
10-60V DC or 8-42V
AC
GPS Synchronization
Yes
Yes
Yes
Interruption cycle
Range: 0.1 - 999.9s
Increments: 100 mS
Range: 0.1 - 999.9s
Increments: 100 mS
Range: 0.1 - 999.9s
Increments: 100 mS
Auxiliary relay drive
capacity
0.5 A
0.5 A
0.5 A
Operating temperature
-30 °C to +70 °C
CD visible from -20
°C to +60 °C
-30 °C to +70 °C
LCD visible from -20
°C to +60 °C
-30° C to +70° C
LCD visible from -20
°C to +60 °C
Programmable
schedules
9 programmable
schedules
start phase: on/off
9 programmable
schedules
start phase: on/off
9 programmable
schedules
start phase: on/off
Display and enclosure
LCD display
fully waterproof case
transparent cover
LCD display
fully waterproof case
transparent cover
LCD display
fully waterproof case
transparent cover
Dimensions
6.0" x 4.5" x 2.8"
6.0" x 4.5" x 4" (with
magnets attached)
6.0" x 4.5" x 4" (with
magnets attached)
Weight
1 lbs. 11 oz. (0.77 kg)
3 lbs. 1 oz. (1.39 kg)
3 lbs. 1 oz. (1.39 kg)
Integrated solid-state
relay
N/A
Load current: Refer to
Load voltage: 100 V
Peak DC
70 V Peak AC
Type: Normally
Closed, Solid State
Load current: Refer to
Load voltage: 100V
peak DC
70V peak AC
Type: Normally
Closed, Solid State
Table B-1. Interrupters Specifications