Interrupters User Guide
Chapter 5: Interrupter Programming
44
Time Zone
UTC
Mountain Standard Time
–07
Pacific Standard Time
–08
Eastern Daylight Time
–04
Central Daylight Time
–05
Mountain Daylight Time
–06
Pacific Daylight Time
–07
Table 5-1. Time Zone and UTC Examples cont'd
1.
To change the relay output mode, select either
Normally Closed
or
Normally Open
mode
from the
Output Mode
drop-down list.
2.
To change the synchronization, select either
On/Off
or
Off/On
from the
Sync Mode
drop-
down list.
3.
The MicroMax interrupters usually use a GPS reading to take timed measurements. Zero
Crossing allows you to use the instant when the AC crosses zero instead of using a GPS
reading. To enable zero crossing for timed measurements, select
Enabled
from the
Zero
Crossing Mode
drop-down list.
4.
Click
Save
to save settings or
Cancel
to clear all fields.
Setting Up Interruption Programs
The nine interruption programs can be set up from the main Bullhorn Tools window.
Complete the following steps to set up Interruption Program 1 through Program 9: