Interrupters User Guide
Chapter 5: Interrupter Programming
36
1.
With the main menu displaying, press
4
on the keypad to display the Options menu.
Figure 5-1. Options Menu
2.
Complete any of the following steps:
a.
To set output parameters, continue with
b.
To set the UTC offset, continue with
Setting the UTC Offset on page 37
c.
To enable or disable zero crossing, continue with
Using Zero Crossing on page 38
d.
To reset the interrupter to factory default settings, continue with
Defaults with Keypad on page 38
.
Output Parameters
Output parameters are set to accommodate various current switch configurations and enable
synchronization with other interrupters.
Switch
can be set to normally open (low output is off) or
normally closed (low output is on). The default setting is
Norm Open
.
Synchronization (
Int. Cycle
) can be set as
OFF/ON
or
ON/OFF
. The setting indicates which portion
of the interruption cycle executes first on the synchronization event. The default setting is
ON/OFF
.
Complete the following steps to set output parameters:
1.
From the main menu, press
4
on the keypad to display the Options menu.
Figure 5-1. Options Menu
2.
Press
5
on the keypad to display the Out Parameters screen.