Interrupters User Guide
Chapter 4: GPS360 Installation
26
icon changes to reflect the power level of the battery. Also, as long as the interrupter is
attached to an alternate power sources, such as a USB connection to a computer, the plug icon
will display.
Interrupter Programming on page 30
for more information on configuring the GPS360.
Connecting an External Relay with Line Power
The GPS360 can be used with an external relay in place of the internal one. If you are going to use an
external relay, the GPS360
must
be connected to line power, such as to the rectifier.
1.
Connect the power cable to the interrupter. Line up the notch on the power cable to the
connection on the interrupter. Twist ring on cable to lock the cable into the connection.
Figure 4-1. Power Cable and MicroMax Interrupter Connection
2.
Connect the external relay control or coil to the power cable
OUTPUT
. Be sure to observe
proper polarity, especially if a flyback diode is present on a mercury relay coil.
Figure 4-2. Power Cable Connections
3.
Connect the AC/DC Power Input cable to the power cable's
INPUT
connection.