Interrupters User Guide
Appendix C: Derating Tables
60
Ambient Temperature
Maximum Current (A)
Celsius
Fahrenheit
Setup 1
Setup 2
25°
77°
83
100
35°
95°
76
100
45°
113°
66
90
55°
131°
56
80
65°
149°
42
65
Table C-1. GPS360 Derating Table
For
Setup 1
, the GPS360 can be in any orientation with the mounting magnets attached for easy
installation.
For
Setup 2
, the GPS360 mounting magnets have been removed, and the heatsink (the full back
surface of the unit) is in full contact with the metal surface of the rectifier enclosure, or with another
metal plate or box, to ensure good temperature regulation.