background image

PHASE 7

OPL

USER’S MANUAL

American Dryer Corporation

88 Currant Road

Fall River, MA 02720-4781

Telephone: (508) 678-9000 / Fax: (508) 678-9447

E-mail: [email protected]

www.amdry.com

071999SC/cms

ADC

 Part No. 113100

Содержание PHASE 7 OPL

Страница 1: ...SE 7 OPL USER S MANUAL American Dryer Corporation 88 Currant Road Fall River MA 02720 4781 Telephone 508 678 9000 Fax 508 678 9447 E mail techsupport amdry com www amdry com 071999SC cms ADC Part No 113100 ...

Страница 2: ...pts in engineering design and safety If this product is properly maintained it will provide many years of safe efficient and trouble free operation We have tried to make this manual as complete as possible and hope you will find it useful ADC reserves the right to make changes from time to time without notice or obligation in prices specifica tions colors and material and to change or discontinue ...

Страница 3: ...IQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE DO NOT USE DRYER IN THE PRESENCE OF DRY CLEANING FUMES DO NOT DRY MOP HEADS IN THE DRYER WARNING CHILDREN SHOULD NOT BE ALLOWED TO PLAY ON OR IN THE DRYERS CHILDREN SHOULD BE SUPERVISED IF NEAR DRYERS IN OPERATION CAUTION DRYERS SHOULD NEVER BE LEFT UNATTENDED WHILE IN OPERATION IMPORTANT PLEASE OBSERVEALLSAFETY PRECAUTIONS displayed on the equ...

Страница 4: ... Conversion Status 4 N Hi Temperature Protection 4 O Cycle Preview 5 P Reversing Option 5 Q RPM 5 R Clean Lint 5 S Language Selection 5 T Model Selection 5 U L E D Display Modes 5 V Factory Settings 5 W Keypad Symbols 5 SECTION III PROGRAM SELECTIONS 6 A Preprogrammed Cycles 6 B Manually Loaded Cycles 7 C Automatic Drying Cycle 8 D Timed Manual Drying Cycle Operation 10 E Temperature Selections 11...

Страница 5: ...TORY PRESET PARAMETERS PROGRAMS 49 A CYCLE A F Parameters Programs Preset by Factory 49 B CYCLE 0 99 Parameters Programs Preset by Factory 49 SECTION VIII PHASE 7 OPL PROGRAMMING LIMITS 50 A Preprogrammed Cycles 50 B System Parameters Program Locations 50 C Fixed Parameters 50 SECTION IX PHASE 7 AUTO CYCLE Patent No 4 827 627 A and B FACTORS 51 SECTION X PHASE 7 OPL SYSTEM DIAGNOSTICS 53 A Diagnos...

Страница 6: ...tomatic Drying Cycle The Phase 7 OPL Automatic Drying Cycle Patent No 4 827 627 principle is based on one of the most fundamental laws of thermodynamics which governs the flow of heat in thermal systems Utilizing this microprocessor technology the user simply has to place the load in the dryer and push one single button to start drying cycle The Phase 7 OPL microprocessor controller com puter will...

Страница 7: ... Cool Down Program Lowers the temperature of the exhaust to make the material cool enough to handle I L E D Display informs user of cycle status programs and displays important diagnostic and faultcodes J Wrinkle Guard Program helps keep items wrinkle free when they are not removed from the dryer promptly at the end of the drying and cooling cycles K Diagnostics major circuits including the door s...

Страница 8: ...e the microprocessor locks the user out Once the feature prompts the user to CLEAN LINT DRAWER the dryer is now in a locked state and will not be cleared until the Lint Drawer has been cleaned When the Lint Drawer is opened the display will read LINT DRAWER OPEN and when the Lint Drawer is closed the display will read READY NOTE the Lint Drawer must be opened for 15 seconds or more for the reset t...

Страница 9: ...he Cool Down Cycle where the articles are tumbled at room temperature Once the programmed Cool Down Cycle is completed the Phase 7 OPL microprocessor controller computer will go to the next step Wrinkle Guard When the cooling cycle is completed the dryer will go into the Wrinkle Guard Cycle Where the load will be tumbled without heat for 2 minutes It will then Stop for 2 minutes This process is re...

Страница 10: ...gree increments f The Spin Time can be programmed from 30 seconds to 120 seconds in one second increments This is done in COOL DOWN Menu g The Stop Dwell Time can be programmed from 7 seconds to 10 seconds in one second increments This is done in COOL DOWN Menu All six A F preprogrammed cycles along with cycles 0 99 have been programmed by the factory as outlined on page 49 However even though cyc...

Страница 11: ... increments c Drying Temperature programmable from 100 F to 200 F in one degree increments or from 37 C to 93 C in one degree increments d The operator has the choice of Reverse or No Reverse single direction rotation depending on what it has been set for in DRYER SETUP The choice is SELECT REVERSE or ALWAYS REVERSE e Press ENTER START This will start the cycle C AUTOMATIC DRYING CYCLE Mode Patent...

Страница 12: ...am selections are 1 through 9 in increments of one 1 b Factor B Heat Loss offset Program this factor setting is dependent upon the model dryer and the type of heating unit 1 Program selections are 1 through 99 in increments of one 1 The Manually Loaded Auto Cycle has the A and B Factors set in DRYER SETUP The A F and 0 99 cycles that have been selected to be Auto have separate Factors for each cyc...

Страница 13: ...en selected to be Manual have separate settings for all the parameters contained in the COOL DOWN SETUP menu Timed Manual Cycle Mode Selections 1 Drying Time programmable from 0 to 99 minutes in one minute increments 2 Cool Down Time programmable from 0 99 minutes in one minute increments 3 Drying Temperature programmable from 100 F to 200 F in one degree increments or from 37 C to 93 C in one deg...

Страница 14: ...rements NOTE The Cool Down Cycle will run either until the Cool Down Temperature is reached or until the Cool Down Time has expired whichever comes first 2 Manually Loaded Cycles a Automatic Drying Cycle Mode Patent No 4 827 627 1 Cool Down Time 0 to 99 minutes in one minute increments 2 Cool Down Temperature 70ºF to 100ºF in one degree increments or from 20ºC to 37ºC in one degree increments NOTE...

Страница 15: ... Character This mode will scroll every message that exceeds the display limit from left to right dropping off a character at a time 1 Scroll Type a One Time This will scroll the message once and stop at the beginning of the message b Continuous With Pause This will scroll the message then pause a brief second at the beginning of the message before scrolling again This will happen continuously c Co...

Страница 16: ...n is made in SYSTEM TEMP Programs affected are 1 Temperature Display Mode 2 Temperature Selections drying temperatures 3 Cool Down Temperatures IMPORTANT When changing the temperature conversion status from Fahrenheit or Celsius or vice versa ALL the Temperature Selections and Cool Down Temperatures will be changed accordingly The Phase 7 OPL microprocessor controller computer automatically calcul...

Страница 17: ...uard cycle can be programmed to be ON OFF This is done in WRINKLE GUARD SETUP Wrinkle Guard Program Selections 1 Wrinkle Guard Audio Alert On Off The operator can select to turn on or off the beeps at the end of each Wrinkle Guard cycle K AUDIO ALERT SIGNAL The tone will sound at the end of the Cool Down Cycle to indicate that the cycle is complete Programming allows for the elimination of the ton...

Страница 18: ...op Time 7 seconds 4 Basket tumbler Spin Time and Dwell Stop Time a Programmable in the Manual Mode 1 Spin Time programmable from 30 seconds to 120 seconds in one second increments 2 Dwell stop Time programmable from 7 seconds to 10 seconds in one second increments N DIAGNOSTICS The Phase 7 OPL microprocessor controller computer monitors both Drying and Mechanical function they are as follows 1 Dry...

Страница 19: ...ions All programmable parameters other than preprogrammed cycles are done here 0 DRYER SETUP All parameters that pertain to drying are in this menu level 0 SELECT MODEL This allows the selection of the heat source applied to the dryer GAS DOUBLE BURNER GAS SINGLE BURNER STEAM 1 SYSTEM TEMP This selection controls whether the temperature related programs will be operated in Fahrenheit ºF or Celsius...

Страница 20: ...ould fail and is being replaced The replacement Phase 7 OPL microprocessor controller computer MUST BE PROGRAMMED for the particular dryer model and heating unit as shown in the A and B Factor table on page 51 of this manual 4 ENTER B FACTOR 1 TO 99 this parameter program is one of the factors that the Phase 7 OPL microprocessor controller computer uses when programmed in the Automatic Drying Cycl...

Страница 21: ... Cycle Patent No 4 827 627 when the manually loaded cycle is selected 1 ENTER COOL DOWN TEMPERATURE This parameter program affects ONLY the Automatic Drying Cycle Patent No 4 827 627 when the manually loaded cycle is selected The Cool Down Temperature is programmable from 70ºF to 100ºF in one degree increments and from 20ºC to 37ºC in one degree increments 2 ENTER SPIN TIME 30 TO 120 SECONDS This ...

Страница 22: ...ill be stored in memory for that number key s This will allow the operator to utilize preprogrammed drying cycles stored in memory under a numerical location NOTE BOTH THE A F AND 0 99 ALLOWS FOR A TOTAL OFF 106 PREPROGRAMMED LOCATIONS FOR CUSTOM DRYING 4 DEFAULT SETTINGS This menu allows the operator to set ALL the programmable parameters to the default settings This option has a password selecti...

Страница 23: ... 1 L E D display reads READY no cycle in progress 2 Press the letter on the keyboard touchpad corresponding to the cycle desired i e Key A NOTE 0 99 WILL REQUIRE THE START ENTER KEY TO BE PRESSED AFTER THE NUMBER IS SELECTED IN ORDER TO ACCEPT THE SELECTION AND START DRYING 3 The dryer will then start i e Blower tumbler and heat 4 L E D display reads AUTO DRYING CYCLE A ELAPSED TIME__ MIN 00 00 Du...

Страница 24: ...R STOP key may be pressed at any time to end the Wrinkle Guard cycle Mechanical functions of the dryer are allowed during the OFF time b Timed Manual Drying Cycle 1 L E D display reads READY no cycle in progress 2 Press the letter on the keyboard touchpad corresponding to the cycle desired i e Key D NOTE 0 99 WILL REQUIRE THE START ENTER KEY TO BE PRESSED AFTER THE NUMBER IS SELECTED IN ORDER TO A...

Страница 25: ...60 TO 200 Defaults to 160 F or 71 C Enter the temperature desired from 160ºFto200ºFinone degreeincrementsorfrom71ºC to 93ºC in one degree increments i e for 180 ºF press Key 1 Key 8 Key 0 and then press the ENTER START Key to accept the value 4 L E D display will now read ENTER DRY LEVEL 90 TO 100 enter the percentage of extraction dryness level desired from 90 to 100 in one percent increments Def...

Страница 26: ...will start to rotate without heat for 2 minutes The Phase 7OPL microprocessor controller computer will repeat this process until the Maximum Wrinkle Guard On Time has expired 99 minutes The L E D display will then read CYCLE DONE and lockout the dryer functions until the doors are opened It will then return to READY NOTE Mechanical functions of the dryer are not allowed during the ON time The Blow...

Страница 27: ...et in Audio Alert ON time The L E D display will read WRINKLE GUARD The times are fixed at 2 minutes OFF 2 minutes ON for a max time of 99 minutes These times are not programmable During the ON time the Blower fan and the basket tumbler will start to rotate without heat for 2 minutes The Phase 7 OPL microprocessor controller computer will repeat this process until the Maximum Wrinkle Guard On Time...

Страница 28: ... the CLEAR STOP key will cancel the program and return to the READY state 6 Use the UP and DOWN ARROWS to scroll through menus or increase decrease number values or toggle between choices 7 In the programming mode the number of keys can be used to jump to menu levels without scrolling through them all i e from 0 select Model in Dryer Setup you can jump to menu level 5 Enter lint count under Dryer ...

Страница 29: ...omatic Drying Cycle a While a cycle is in progress the cycle status will display ELAPSED TIME__MIN During the Drying Cycle the Phase 7 OPL microprocessor controller computer is monitoring the moisture in the load Once the temperature is above 160 F the Cycle Status portion of the L E D will change from ELAPSED TIME __ MIN to __ DRY The display will count upward until the percentage of extraction p...

Страница 30: ... CHARACTER CHECK CONTROL POWER CLEAN LINT DRAWER COMFIRM DEFAULTS CONTINUOUS CONTINUOUS WITH PAUSE COOL DOWN SETUP CYCLE DONE DEFAULT SET DEFAULT SETTINGS DEG C DEG F DEUTSCH DISPLAY SETUP DRY ENABLE FAULT DRYER SETUP ENGLISH ENTER 00 99 ENTER A FACTOR 1 TO 9 ENTER AUDIO ALERT ON TIME 0 TO 10 SECONDS ENTER B FACTOR 1 TO 99 ENTER LINT COUNT 1 TO 5 ENTER COOL DOWN TEMP __ TO __ ENTER COOL DOWN TIME ...

Страница 31: ... OFF ON ONE TIME PIXEL PRESS START PROGRAM 00 99 CYCLE PROGRAM A F CYCLE PROGRAM MODE READY REAR BURNER IGNITION CONTROL FAULT REAR BURNER HIGH LIMIT FAULT REAR BURNER VALVE FAULT REAR DOORS NOT CLOSED REAR NOT DOWN REAR SAIL SWITCH CLOSE FAULT REAR SAIL SWITCH OPEN FAULT ROTATION FAULT ROTATION MODE SELECT A F KEY SELECT CYCLE TYPE SELECT LANGUAGE SELECT MODEL SELECT REVERSE SELECT REVERSE MODE S...

Страница 32: ...29 SYSTEM TEMP TUMBLER OVER LOAD FAULT VIEW CYCLE WRINKLE GUARD WRINKLE GUARD AUDIO ALERT WRINKLE GUARD SETUP YES ...

Страница 33: ...nel ENTERING THE PROGRAMMING MODE First make sure that no cycle is in progress and that the L E D display reads READY then press the CLEAR STOP Key and the UP ARROW key together This will put you into the programming mode EXITING THE PROGRAMMING MODE The CLEAR STOP key will return you to the previous menu level Continue to press the CLEAR STOP key until you are all the way out of the Programming M...

Страница 34: ...E D display will read READY B PROGRAMMING FLOW CHARTS Thefollowingsectionofthismanual page 32 through page 46 explains the programming of the preprogrammed cycles and Program Locations system parameters through the use of flow charts A flow chart is nothing more than a diagram of the programming process Four 4 different symbols will be used in these flow charts a rectangle a square ENTER START CLE...

Страница 35: ... 4 DEFAULT SETTINGS 37 Manually Loaded Cycles Automatic Drying Cycle Patent No 4 827 627 38 Timed Manual Drying Cycle 38 NOTE To review the preset Program Locations simply press the ENTER START key followed by the letter location while the L E D display reads READY To review a number location simply follow the same process as a letter with the addition of the ENTER START key being pressed again af...

Страница 36: ... PROGRAMMING MODE ENTERING MUST BE IN THE READY STATE PRESS STOP CLEAR AND UP ARROW KEY TOGETHER THIS WILL GET YOU INTO THE PROGRAMMING MODE EXITING PRESSING THE STOP CLEAR KEY REPEATEDLY UNTIL YOU ARE BACK TO THE READY DISPLAY THE STOP CLEAR KEY WILL BRING YOU BACK ONE MENU LEVEL AT A TIME AT THE FIRST MENU LEVEL IT WILL EXIT YOU FROM THE PROGRAMMING MODE AND RETURN TO THE READY STATE NOTES THE U...

Страница 37: ...LUE 5 ENTER LINT COUNT 1 TO 5 5 5 DEFAULT VALUE 6 ENTER AUDIO ALERT ON TIMES 0 TO 10 5 5 DEFAULT VALUE 1 DISPLAY SETUP 0 SELECT SCROLL MODE PIXEL CHARACTER 1 SELECT SCROLL TYPE CONTINUOUS WITH PAUSE CONTINUOUS ONE TIME 2 SELECT SCROLL SPEED 1 TO 20 12 12 DEFAULT VALUE 2 COOL DOWN SETUP 0 ENTER COOL DOWN TIME 0 TO 99 MINUTES 3 3 DEFAULT VALUE 1 ENTER COOL DOWN TEMP 70 TO 100 F 100 F 100 F DEFAULT V...

Страница 38: ...IME FOR THAT CYCLE 4 ENTER COOL DOWN TEMP 70 TO 100 F F THE DEFAULT TEMP FOR THAT CYCLE 5 ENTER A FACTOR 1 TO 9 A 5 5 DEFAULT VALUE 6 ENTER B FACTOR 1 TO 99 B 78 78 DEFAULT VALUE MANUAL 0 REVERSE MODE ON OFF 1 ENTER DRY TIME 0 TO 99 MINUTES MIN THE DEFAULT MINUTES FOR THAT CYCLE 2 ENTER DRY TEMP 100 TO 200 F F THE DEFAULT DRY TEMP FOR THAT CYCLE 3 ENTER COOL DOWN TIME 0 TO 99 MINUTES MIN THE DEFAU...

Страница 39: ...MP 70 TO 100 F F THE DEFAULT TEMP FOR THAT CYCLE 5 ENTER A FACTOR 1 TO 9 A 5 5 DEFAULT VALUE 6 ENTER B FACTOR 1 TO 99 B 78 78 DEFAULT VALUE MANUAL 0 REVERSE MODE ON OFF 1 ENTER DRY TIME 0 TO 99 MINUTES MIN THE DEFAULT MINUTES FOR THAT CYCLE 2 ENTER DRY TEMP 100 TO 200 F F THE DEFAULT DRY TEMP FOR THAT CYCLE 3 ENTER COOL DOWN TIME 0 TO 99 MINUTES MIN THE DEFAULT TIME FOR THAT CYCLE 4 ENTER COOL DOW...

Страница 40: ...PASSWORD PRESS 1 2 3 CONFIRM DEFAULTS NO DEFAULT VALUE YES NOTE NO WILL RETURN YOU BACK TO 4 DEFAULT SETTINGS YES WILL SET ALL THE PARAMETERS TO THE DEFAULT SETTINGS DISPLAY WILL READ DEFAULTS SET AND RETURN TO 4 DEFAULT SETTINGS ...

Страница 41: ...100 TO 200 F 100 F 100 DEFAULT VALUE ENTER COOL DOWN TIME 0 TO 99 MINUTES 3 MIN 3 DEFAULT VALUE SELECT REVERSE MODE ON OFF PRESS START ONE TIME AUTO CYCLE FROM READY STATE PRESS AUTO KEY ENTER DRY TEMP 160 TO 200 F 160 F 160 DEFAULT VALUE ENTER DRY LEVEL 90 TO 100 100 100 DEFAULT VALUE SELECT REVERSE MODE ON OFF PRESS START ...

Страница 42: ...H ITALIAN GERMAN I 1 SELECT SYSTEM PARAMETERS I 0 DRYER SETUP I 0 SELECT MODEL I GAS 2 BURNER GAS 1 BURNER STEAM I 1 SYSTEM TEMP 0 0 I DEG F DEG C I 2 REVERSE MODE I SELECT REVERSE ALWAYS REVERSE I 3 ENTER A FACTOR 1 TO 9 I 5 I OR 6 0 0 0 4 2 0 3 5 7 0 1 ...

Страница 43: ...78 I OR 0 5 ENTER LINT COUNT 1 TO 5 I 5 I OR 0 6 ENTER AUDIO ALERT ON TIMES 0 TO 10 I 5 I OR 0 1 DISPLAY SETUP 0 I 0 SELECT SCROLL MODE I PIXEL CHARACTER I 0 1 SELECT SCROLL TYPE I CONTINUOUS W PAUSE CONTINUOUS ONE TIME I 0 9 10 11 12 13 14 1 8 ...

Страница 44: ...ER COOL DOWN TIME 0 TO 99 MINUTES I 0 3 I OR 1 ENTER COOL DOWN TEMP 70 TO 100 F I 0 100 I OR 2 ENTER SPIN TIME 30 TO 120 SECONDS I 0 60 I OR 2 ENTER STOP TIME 7 TO 10 SECONDS I 0 7 I OR 16 17 3 WRINKLE GUARD SETUP 0 I 0 WRINKLE GUARD AUDIO ALERT I 0 AUDIO ALERT ON AUDIO ALERT OFF I 8 15 ...

Страница 45: ... A I B C D E F OR SELECT CYCLE TYPE AUTO MANUAL 0 0 I 0 0 REVERSE MODE I I ON OFF 0 1 ENTER DRY TEMP 160 TO 200 F I 0 160 I OR 2 ENTER DRY LEVEL 90 TO 100 I 0 100 I OR 3 ENTER COOL DOWN TIME 0 TO 99 MINUTES I 0 10 I OR 22 23 24 18 I 21 0 19 20 15 ...

Страница 46: ... I 5 I OR 0 6 ENTER B FACTOR 1 TO 99 I 78 I OR 0 0 REVERSE MODE I I ON OFF 0 2 ENTER DRY TEMP 100 TO 200 F I 0 100 I OR 1 ENTER DRY TIME 0 TO 99 MINUTES I 0 30 I OR 3 ENTER COOL DOWN TIME 0 TO 99 MINUTES I 0 10 I OR 4 ENTER COOL DOWN TEMP 70 TO 100 F I 70 I OR 0 18 25 28 29 19 20 26 27 ...

Страница 47: ...ER SPIN TIME 30 TO 120 SECONDS I 60 I OR 0 6 ENTER STOP TIME 7 TO 10 SECONDS I 7 I OR 0 25 26 27 3 PROGRAM 0 99 CYCLE I SELECT 0 99 CYCLE 0 0 I 1 2 3 99 OR SELECT CYCLE TYPE 0 AUTO MANUAL 0 I 0 I 33 30 31 32 34 35 36 ...

Страница 48: ...F I 0 160 I OR 2 ENTER DRY LEVEL 90 TO 100 I 0 100 I OR 3 ENTER COOL DOWN TIME 0 TO 99 MINUTES I 0 10 I OR 33 30 31 32 34 35 36 4 ENTER COOL DOWN TEMP 70 TO 100 F I 70 I OR 0 5 ENTER A FACTOR 1 TO 9 I 5 I OR 0 6 ENTER B FACTOR 1 TO 99 I 78 I OR 0 40 37 38 39 41 ...

Страница 49: ...RY TIME 0 TO 99 MINUTES I 0 30 I OR 3 ENTER COOL DOWN TIME 0 TO 99 MINUTES I 0 10 I OR 4 ENTER COOL DOWN TEMP 70 TO 100 F I 70 I OR 0 5 ENTER SPIN TIME 30 TO 120 SECONDS I 60 I OR 0 6 ENTER STOP TIME 7 TO 10 SECONDS I 7 I OR 0 4 DEFAULT SETTINGS I 0 ENTER PASSWORD 1 2 3 I CONFIRM DEFAULTS I NO YES 0 ...

Страница 50: ...DRY TEMP 100 TO 200 F 0 100 I OR ENTER DRY TIME 0 TO 99 MINUTES 0 0 I OR ENTER COOL DOWN TIME 0 TO 99 MINUTES 0 3 I OR 0 I ON OFF SELECT REVERSE MODE 0 PRESS START 0 I THE CYCLE WILL START WITH THE PARAMETERS SELECTED ONCE THE START KEY IS PRESSED ...

Страница 51: ...LE AUTO READY AUTO ENTER DRY TEMP 160 TO 200 F 0 160 I OR ENTER DRY LEVEL 90 TO 100 0 100 I OR 0 I ON OFF SELECT REVERSE MODE 0 PRESS START 0 I THE CYCLE WILL START WITH THE PARAMETERS SELECTED ONCE THE START KEY IS PRESSED ...

Страница 52: ...5 B Factor 78 CYCLE D Manual Timed Mode Reverse Dry Time 40 minutes Dry Temperature 190ºF Cool Down Time 6 minutes Cool Down Temperature 80ºF Spin Time 60 seconds Stop Dwell Time 7 seconds CYCLE E Manual Timed Mode Reverse Dry Time 30 minutes Dry Temperature 180ºF Cool Down Time 4 minutes Cool Down Temperature 80ºF Spin Time 60 seconds Stop Dwell Time 7 seconds CYCLE F Manual Timed Mode Reverse Dr...

Страница 53: ...0ºF to 200ºF in one degree increments b Drying Time from 0 to 99 minutes in one minute increments c Cool Down Time from 0 to 99 minutes in one minute increments for preprogrammed cycle d Cool Down Temperature from 70ºF to 100ºF in one degree increments e Reversing Models 1 Automatic Cycle Patent No 4 827 627 Spin time and Stop time is not programmable Refer to Fixed Parameters on part C 2 Timed Cy...

Страница 54: ...r particular model dryer A B factor is not shown in above chart contact the ADC Service Department for the appropriate factors for your particular dryer When doing so please have the dryer model and serial number available GAS DOUBLE BURNER MODEL A B ADG 310 ADG 410 STEAM MODEL A B ADS 200 ADS 310 ADS 410 GAS SINGLE BURNER MODEL A B ADG 200 5 78 5 5 78 65 5 5 72 72 65 5 ...

Страница 55: ...HASE 7 OPL MICROPROCESSOR CONTROLLER COMPUTER MUST BE REPROGRAMMED FOR THE SPECIFIC MODEL SHOWN IN THE A and B FACTOR PARAMETERS CHART ON THE PREVIOUS PAGE page 51 The A B FACTOR LABEL IS LOCATED IN THE TOP CONTROL PANEL BEHIND THE PHASE 7 KEYPAD DISPLAY DOOR NOTE For fine tuning the Auto Cycle for certain loads If cloths come out wet then decrease the B Factor if cloths come out too dry increse t...

Страница 56: ...OSED A Rear Door is open when it should be closed CHECK CONTROL POWER Indicates Control Power is Off EXHAUST HIGH TEMP FAULT Indicates the temperature in the Tumbler is above 225 F LINT DRAWER OPEN Indicates the Lint Drawer is open and needs to be closed DRY ENABLE FAULT Indicates the machine is not level and all doors closed Not ready to start drying FRONT NOT DOWN Machine is tilted back REAR NOT...

Страница 57: ...EAR BURNER VALVE FAULT Indicates Rear Gas Valve is not working or no gas is turned on or flame out FRONT BURNER IGNITION CONTROL FAULT Front ignition module is not working or failure to ignite REAR BURNER IGNITION CONTROL FAULT Rear ignition module is not working or failure to ignite ROTATION FAULT Indicates the Tumbler is not rotating BAD PROBE Indicates the temperature probe is open or shorted L...

Страница 58: ...ammable Output 2 11 R_SS Rear Sail Switch 11 PRG3 Programmable Output 3 12 FBHL Front Burner High Limit 12 PRG4 Programmable Output 4 13 F_SS Front Sail Switch 13 OCL1 Open Collector 1 14 EXHL Exhaust High Limit 14 OCL2 Open Collector 2 15 DRY Dry Enable Bit 15 OCL3 Open Collector 3 16 LINT Lint Drawer 16 OCL4 Open Collector 4 17 24VM Control Voltage at Spare Inputs 17 OCL5 Open Collector 5 18 FVL...

Страница 59: ...s ON 9 FAN RED LED This LED will indicate the status of the Blower Fan If the fan is on Then the LED is ON 10 RBHL RED LED This LED will indicate the status of the Rear Burner High Limit Disk If the disk is closed Temp below 330 F Then the LED is ON 11 R_SS RED LED This LED will indicate the status of the Rear Sail Switch If the switch is closed Then the LED is ON 12 FBHL RED LED This LED will ind...

Страница 60: ... LED This is for a spare input to be used with programmable outputs 22 SPR3 RED LED This is for a spare input to be used with programmable outputs 23 SPR4 RED LED This is for a spare input to be used with programmable outputs 24 SPR5 RED LED This is for a spare input to be used with programmable outputs 25 24 RED LED This LED will indicate the board voltage that is protected by Fuse 2 26 24IN RED ...

Страница 61: ...output If the request to turn on the Front Heater is made then the LED is On 8 AUX GREEN LED This is for a spare output to be programmed 9 PGR1 GREEN LED This is for a spare output to be programmed 10 PGR2 GREEN LED This is for a spare output to be programmed 11 PGR3 GREEN LED This is for a spare output to be programmed 12 PGR4 GREEN LED This is for a spare output to be programmed 13 OCL1 GREEN LE...

Страница 62: ...ulted to Rear Door Open 19 OCL7 GREEN LED This LED will indicate the status of the Open Collector 7 output If the request to turn on the Open Collector 7 is made then the LED is On Program mable and Defaulted to Rear Door Closed 20 OCL8 GREEN LED This LED will indicate the status of the Open Collector 8 output If the request to turn on the Open Collector 8 is made then the LED is On Program mable ...

Страница 63: ...ADC 113100 1 08 19 99 25 2 09 30 99 25 3 01 05 00 20 4 02 05 00 20 5 06 05 00 20 6 08 29 00 50 7 10 24 00 25 8 12 26 00 25 9 03 15 01 25 10 04 25 01 25 ...