21
2. Electrical Service Specifications
IMPORTANT:
The dryer
must be
connected to the electric supply shown on the data label that is
affixed to the left side panel area behind the top control (access) door (refer to the
illustration
on
page 9
). In the case of 208 VAC or 240 VAC, the supply voltage
must match the electric service specifications of the data label
exactly
.
WARNING: 208 VAC AND 240 VAC ARE
NOT
THE
SAME
. Any damage done to dryer
components due to improper voltage connections will automatically VOID THE
WARRANTY.
NOTE: ADC
reserves the right to make changes in specifications at any time without notice or
obligation.
ML-122 (Gas and Steam Only)
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT
:
NOTES
: A.
B.
C.
208 VAC AND 240 VAC
ARE NOT THE SAME. When ordering,
specify
exact voltage
.
When fuses are used they
must be
dual element, time delay, current limiting, class RK1 or RK5
ONLY
. Calculate/determine correct fuse value, by applying either local and/or National Electrical
Codes to listed appliance amp draw data.
Circuit breakers are thermal-magnetic (industrial) motor curve type
ONLY
. For others, calculate/
verify correct breaker size according to appliance amp draw rating and type of breaker used.
Circuit breakers for 3-phase (3Ø) dryers
must be
3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
MINIMUM
WIRE SIZE
FUSING
CIRCUIT
BREAKER
Dual Element
Time Delay
60 Hz
50 Hz
208
3Ø
3/4
12.6
--
*
20
25
240
3Ø
3
11
12.5
*
20
20
380-400
3Ø
3/4
--
5.5
*
15
15
416
3Ø
3/4
--
5.6
*
15
15
460/480
3Ø
3/4
8.6
--
*
15
15
* AWG Stranded Wire Type...size wire as per National Electrical Code or local codes.