Cleaning, maintenance and repairs
ZA-M BAG0040.8 09.15
95
12.7
Checking the horizontal position of the leaf springs and bearing straps
Fig. 55/...
(1) Weighing frame
(2) Weighing cell
(3) Leaf spring
(4) Bearing strap
(5) Micrometer
(6) Check screw
(7) Support block
(8) Lock nut
The leaf springs and bearing straps must be in
horizontal position, as otherwise the measure-
ment result will be falsified.
At the factory, the leaf springs and bearing straps
are installed horizontal.
After a fertilise quantity of approx. 10.000 has
been spread, the micrometer may have become
settled or worked into the support block. This
may displace the leaf springs from the horizontal.
In this case, the micrometer must be reset until
the leaf springs and bearing straps are again
aligned horizontally.
Fig. 55
Align leaf springs and bearing straps
only when the spreader is empty!
The micrometer is located centrally under the
frame of the spreader in the weighing cell.
For this purpose:
1. Release the lock nut.
2. Reset the micrometer
3. Tighten the lock nut.
After performing the setup tasks for
the micrometer on the angular gear-
box, carry out the following:
•
Calibrate the spreader. (See
operating manual for software
AMABUS / ISOBUS).
•
Adjust the clearance for the
check screw.