![Amazone ZA-M Profis Hydro Скачать руководство пользователя страница 86](http://html1.mh-extra.com/html/amazone/za-m-profis-hydro/za-m-profis-hydro_operating-manual_2919788086.webp)
Faults
86
ZA-M BAG0040.8 09.15
11.3
Faults, causes and remedies
Fault
Cause
Remedy
Fertiliser lateral distribution not
uniform
Fertiliser deposits on the spread-
ing discs and the spreading
vanes.
Clean the spreading discs and
the spreading vanes.
Sliders do not open all the way.
Too much fertiliser in the tractor
track
Prescribed spreading disc speed
is
not
reached.
Increase tractor engine speed.
Spreading vanes and outlets
defective or worn.
Check the spreading vanes and
outlets. Replaced defective or
worn parts immediately.
The spreading properties of your
fertiliser differ from those of the
one we tested when creating the
setting chart.
Contact the
AMAZONE
Fertiliser Service.
05405-501-111
Too much fertiliser in the overlap
area
Prescribed spreading disc speed
is exceeded.
Reduce tractor engine speed.
The spreading properties of your
fertiliser differ from those of the
one we tested when creating the
setting chart.
Contact the
AMAZONE
Fertiliser Service.
+49 5405 501 - 111
Both hopper tips do not empty
uniformly at the identical slider
position
Bridging of fertiliser.
Eliminate cause of bridging.
R-clip in the spiral agitator has
shorn off due to overloading.
Replace R-clip.
Basic settings of the sliders differ Check basic settings of the slid-
ers.
Hydraulic cylinders are not open-
ing or closing
Fluid supply at the tractor is not
switched on.
Switch on fluid supply at the trac-
tor.
Power supply to valve block in-
terrupted.
Check cable, plug and contacts.
Oil filter contaminated.
Replace/clean oil filter.
Solenoid valve contaminated.
Rinse solenoid valve.
The temperature of the hydraulic
fluid is too high in a tractor
equipped with a constant flow
system (gear pump)
The system converting bolt on
the spreader valve block has not
been unscrewed to the limit stop
(factory setting).
Unscrew the system converting
bolt on the spreader valve block
until it reaches the limit stop
Defective plug couplings
Check plug couplings, re-
pair/replace as required.
Defective tractor control unit
Check tractor control unit, re-
pair/replace as required.