Cleaning, maintenance and repair
242
Pantera 4504 CP plus BAG0230.2 07.21
15.7.12
230B
Air conditioner
15.7.12.1
259B
Put the air conditioning system into operation
In order to prevent damage to the compressor
with machines fitted with air conditioner, the air
conditioner should be put back into operation
after longer standing times.
The commissioning makes sure that the oil is
distributed in the air conditioner.
1. Switch on the diesel engine and run in idle
speed.
2. Open all fan jets completely.
3. Open both doors.
4. Switch on the air conditioner.
5. Set the temperature controller (1) to the
lowest temperature.
6. Blower to level 3 or automatic mode.
7. Allow the machine to run for minimum 5
minutes at idle speed.
The air conditioning system can now be operated
as normal.
15.7.12.2
260B
Working with refrigerant
DANGER
Death or severe injuries resulting from refrigerant.
Work on the air conditioning system may only be carried by an
authorised workshop.
Avoid any contact with the refrigerant.
Wear protective gloves and protective goggles.
No welding tasks may be carried out on the refrigerant circuit
and in their immediate vicinity.
Maximum ambient temperature for refrigerant: 80° Celsius
Содержание Pantera 4504
Страница 2: ...2 Pantera 4504 CP plus BAG0230 2 07 21 Leipzig Plagwitz 1872 ...
Страница 20: ...General Safety Instructions 20 Pantera 4504 CP plus BAG0230 2 07 21 ...
Страница 259: ...Diagrams and overviews Pantera 4504 CP plus BAG0230 2 07 21 259 16 1 Liquid circuit part width section control ...
Страница 263: ...Diagrams and overviews Pantera 4504 CP plus BAG0230 2 07 21 263 ...
Страница 267: ...Diagrams and overviews Pantera 4504 CP plus BAG0230 2 07 21 267 16 4 2 238BFuses and relay in the cabin roof ...
Страница 277: ...Spray table Pantera BAG0230 2 07 21 277 ...
Страница 286: ......