9.1.9 Cleaning the segment distributor head
INTERVAL
Every 10 operating hours
or
daily
NOTE
The segment distributor head must be kept free of
dust, deposits, and foreign objects.
Shorten the checking intervals under very dusty
conditions.
1.
Loosen the 4 knurled screws
1
.
2.
Remove the cover
2
.
3.
Clean the segment distributor head
3
using a
paint brush, hand brush or with compressed air.
4.
Clean the seed outlets and tramline segments
4
using a paint brush, hand brush or with
compressed air.
5.
Install the cover.
6.
Tighten the 4 knurled screws by hand.
CMS-I-00003133
9.1.10 Checking the top link pin and lower link pin
INTERVAL
daily
1.
Check the top link pins and lower link pins for
cracks or broken areas.
Permissible wear
2 mm
2.
Replace the pins if there is significant wear.
CMS-T-00004448-C.1
CMS-T-00002330-E.1
9 | Repairing the machine
Maintaining the machine
MG6545-EN-II | B.1 | 22.07.2021