![Amazone AD-P 3001 Special 850 Скачать руководство пользователя страница 102](http://html1.mh-extra.com/html/amazone/ad-p-3001-special-850/ad-p-3001-special-850_operating-manual_2919700102.webp)
Coupling and uncoupling the implement
102
AD-P 30/35/4001 SPECIAL BAH0095-2 11.17
7.1
Hydraulic hose lines
WARNING
Danger of infection from escaping hydraulic fluid at high pres-
sure!
When coupling and uncoupling the hydraulic hose lines, ensure that
the hydraulic system is depressurized on both the implement and
tractor sides.
If you are injured by hydraulic fluid, contact a doctor immediately.
7.1.1
Coupling the hydraulic hose lines
WARNING
Risk of being crushed, cut, caught, drawn in or struck due to
faulty hydraulic functions when the hydraulic hose lines are
connected incorrectly!
When coupling the hydraulic hose lines, observe the coloured mark-
ings with the code number or code letters on the hydraulic plugs.
Check the compatibility of the hydraulic fluids before connecting
the implement to the hydraulic system of your tractor.
Do not mix any mineral oils with biological oils.
Observe the maximum permitted hydraulic fluid pressure of
210 bar.
Only couple clean hydraulic plugs. Minor oil contamination with
particles can cause a failure of the hydraulic system.
Push the hydraulic plug(s) into the hydraulic socket(s) until the
hydraulic plug(s) perceivably lock(s).
Check the coupling points of the hydraulic hose lines for proper
fit and sealing.