CHAPTER 3: USING PROGRAMMING FUNCTIONS
UNIFLOW
®
4 PULSED HEAT CONTROL
990-908
3-19
The default value is
Medium
. The progression from
Very
Slow
to
Fast
provides more energy to heat the
thermode. Use the table below as a guide to optimizing the coarse heating rate. Select the
recommended coarse heating rate by pressing keys
1
through
4
. Typical
COARSE HEATING RATES
are
Very
Slow
for small peg tip thermodes,
Slow
for 0.4” wide thermodes,
Medium
for 1.5” thermodes, and
Fast
for large thermodes.
Thermode Family Series
Coarse Heating Rate
Very Slow
Slow
Medium
Fast
17T 1
17P 1
2
17BM, up to 10 mm (0.37 in.)
2
3
17BM, 10 to 30 mm (0.37 to 1.2 in.)
2
3
4
17BW, 30 to 60 mm (1.2 to 2.4 in.)
2
3
4
17BW, 60 to 100 mm (2.4 to 4.0 in.)
*
3
4
17F, up to 10 mm (0.37 in.)
2
3
17F, 10 to 30 mm (0.37 to 1.2 in.)
2
3
4
17FW, 30 to 60 mm (1.2 to 2.4 in.)
3
4
17FW, 60 to 100 mm (2.4 to 4.0 in.)
*
3
4
NOTE:
17BW and 17FW thermodes, 60 to 100 mm long, can
only
be heated using 4kVA Models.
Selecting
2
on the
MANUAL TUNING
screen will bring up the
SET FINE HEATING RATE
screen.
The default value is 85%. A value from
85 to 95% is appropriate for 80% of
thermodes. The effective range of the
SET FINE HEATING RATE
is usually in
the 50 to 99 % range. A larger
percentage means that more energy is
available to heat the thermode. A setting
of 85% is typical for small peg tip
thermodes. A setting of 95-97% is
typical of blade and foldup thermodes.
< SET FINE HEATING RATE >
SET FINE HEATING RATE : 85 %
0 10 20 30 40 50 60 70 80 90
◄►
Adjust ,
Page,
Graph
/
Data
Adjustments in the
SET FINE HEATING RATE
can help optimize temperature rise time with overshoot.
Use the
◄►
cursor keys to adjust the fine heating rate, from 0 to 99%. The selected rate will be
displayed graphically as a percentage of the indexed grid, and as a numerical value.
Содержание UNIFLOW 4 REMOTE
Страница 1: ...990 908 REV K PULSED HEAT CONTROL UNIFLOW 4 UNIFLOW 4 REMOTE OPERATION MANUAL ...
Страница 18: ...UNIFLOW 4 PULSED HEAT CONTROL xviii 990 908 ...
Страница 19: ...UNIFLOW 4 PULSED HEAT CONTROL 990 908 xix ...
Страница 20: ...UNIFLOW 4 PULSED HEAT CONTROL xx 990 908 ...
Страница 21: ...UNIFLOW 4 PULSED HEAT CONTROL 990 908 xxi ...
Страница 26: ......
Страница 36: ......
Страница 50: ......
Страница 96: ......
Страница 106: ......
Страница 137: ...UNIFLOW 4 PULSED HEAT CONTROL 990 908 C 1 APPENDIX C SYSTEM TIMING No Post Heat Pulse TCOOL1 Cool1 Temperature Setpoint ...
Страница 176: ...AMADA MIYACHI AMERICA INC 1820 South Myrtle Ave Monrovia CA 91016 U S A TEL 1 626 303 5676 FAX 1 626 358 8048 ...