CHAPTER 2: INSTALLATION AND SETUP
UNIFLOW
®
4 PULSED HEAT CONTROL
2-10
990-908
Section III: Equipment Setup
Force Fired, Mechanically Actuated Head
NOTE:
If you are using an Air Actuated Head, skip this section and go the next page for the
Force
Fired Air Actuated Head
instructions.
1.
Adjust the reflow soldering head force adjustment knob to produce 5 units of force, as
displayed on the force indicator index.
2.
Connect the reflow soldering head firing switch cable connector to the Control firing switch
INITIATE
cable connector.
3.
Set the
HEAT/NO HEAT
switch on the Control front panel to the
NO HEAT
position. In this
position, the Control cannot deliver heating energy to the thermode.