APPENDIX A: TECHNICAL SPECIFICATIONS
UNIFLOW
®
4 PULSED HEAT CONTROL
A-8
990-908
STANDARD
Version
●
115 VAC
Configuration
Switch
S1
is set with
115V
visible on the switch.
The factory-supplied
115V/230V
jumper with the
BROWN
wires is installed on connector
J7
as shown.
STANDARD
Version
●
230 VAC
Configuration
Switch
S1
is set with
230V
visible on the switch.
The factory-supplied
115V/230V
jumper with the
BROWN
wires is installed on connector
J7
as shown.
REMOTE
Version
●
230 VAC
Configuration
Switch
S1
is set with
230V
visible on the switch.
The factory-supplied
230V
jumper with the
BLUE
wires is installed on connector
J7
as shown.