CHAPTER 1: DESCRIPTION
UNIFLOW
®
4 PULSED HEAT CONTROL
1-6
990-908
Numerical Keypad
The keypad allows you to edit the numeric values of the display
screens.
The keypad also allows you to enter in the alphanumeric schedule
reference which is displayed on the graphic screen
Cursor Keys
The cursor keys allow you to move the editing cursor up, down and sideways.
You use the
▲
(Up) and
▼
(Down) keys to select multiple pages in a single
menu or setup screen. You use the
◄
(Left) and
►
(Right) keys to decrease or
increase a numeric field value. After changing the temperature or time
parameters using the keypad, the
▲
(Up) key will save your change. The
▲
(Up) key will also clear alarm messages and the
ALARM
and
OUT OF LIMITS
of
relay state.
Graph Key
This key displays the graphic screen for editing the heat profile parameters
with the keypad or cursor keys. After editing the heat profile parameters,
pressing the
GRAPH
key saves the new parameters to the heat profile noted on
the display. Pressing the
GRAPH
key while in the setup, counter, or heating
rate menus returns the Control to the graphic display mode.
Содержание UNIFLOW 4 REMOTE
Страница 1: ...990 908 REV K PULSED HEAT CONTROL UNIFLOW 4 UNIFLOW 4 REMOTE OPERATION MANUAL ...
Страница 18: ...UNIFLOW 4 PULSED HEAT CONTROL xviii 990 908 ...
Страница 19: ...UNIFLOW 4 PULSED HEAT CONTROL 990 908 xix ...
Страница 20: ...UNIFLOW 4 PULSED HEAT CONTROL xx 990 908 ...
Страница 21: ...UNIFLOW 4 PULSED HEAT CONTROL 990 908 xxi ...
Страница 26: ......
Страница 36: ......
Страница 50: ......
Страница 96: ......
Страница 106: ......
Страница 137: ...UNIFLOW 4 PULSED HEAT CONTROL 990 908 C 1 APPENDIX C SYSTEM TIMING No Post Heat Pulse TCOOL1 Cool1 Temperature Setpoint ...
Страница 176: ...AMADA MIYACHI AMERICA INC 1820 South Myrtle Ave Monrovia CA 91016 U S A TEL 1 626 303 5676 FAX 1 626 358 8048 ...