APPENDIX B: ELECTRICAL AND DATA CONNECTIONS
UNIFLOW
®
4 PULSED HEAT CONTROL
990-908
B-13
Alarm/Status Relays Connections For Relays 1
5
NOTE:
See Connector
J6B
for
Relays 6
and
7
. The following relay rating applies to all
Relays 1
through
7
.
ATTENTION:
The previous version Uniflow 4 with part numbers beginning with 1-298-01 had a
Chassis Ground connection on Pin J6A-10. This Chassis Ground connection has been moved to J4A-5
for this new version of Uniflow 4 with part numbers 1-298-02.
Relay
Rating:
30 VAC or 30 VDC at 0.5 Amps
User Programmable Options for Relay States:
System Ready
On/Off when Uniflow 4 Control is ready for reflow operation
Heat On
On/Off during baseheat, rise1, preheat,rise2, reflow and postheat process cycle
Head Is Up On/Off when head is retracted
Alarm On/Off for any alarm condition
Out of Limit On/Off for any out of limit condition
Clean
Thermode
On/Off
when
clean thermode counter expires
Replace Thermode
On/Off when replace thermode counter expires
Idle On/Off if idle temperature On
Baseheat
On/Off
during baseheat process cycle
Rise1 On/Off when 50% of the programmed Rise1 time has elapsed. At the
end of the programmed Rise1 time, the relay will switch back to Off/On
Preheat On On/Off during preheat process cycle
Rise2 On/Off when 50% of the programmed Rise2 time has elapsed. At the end
of the programmed Rise2 time, the relay will switch back to Off/On
Reflow On/Off from start of heating to COOL1 if no Postheat cycle otherwise COOL2
Cool1 On/Off when the COOL1 temperature is reached
End
of
Reflow ON/OFF
when COOL1 is reached if no Postheat cycle, otherwise Cool2
Cycle Pwr Alarm
On/Off for "cycle power" alarm conditions
Not Active
: The relay is not active.
Содержание UNIFLOW 4 REMOTE
Страница 1: ...990 908 REV K PULSED HEAT CONTROL UNIFLOW 4 UNIFLOW 4 REMOTE OPERATION MANUAL ...
Страница 18: ...UNIFLOW 4 PULSED HEAT CONTROL xviii 990 908 ...
Страница 19: ...UNIFLOW 4 PULSED HEAT CONTROL 990 908 xix ...
Страница 20: ...UNIFLOW 4 PULSED HEAT CONTROL xx 990 908 ...
Страница 21: ...UNIFLOW 4 PULSED HEAT CONTROL 990 908 xxi ...
Страница 26: ......
Страница 36: ......
Страница 50: ......
Страница 96: ......
Страница 106: ......
Страница 137: ...UNIFLOW 4 PULSED HEAT CONTROL 990 908 C 1 APPENDIX C SYSTEM TIMING No Post Heat Pulse TCOOL1 Cool1 Temperature Setpoint ...
Страница 176: ...AMADA MIYACHI AMERICA INC 1820 South Myrtle Ave Monrovia CA 91016 U S A TEL 1 626 303 5676 FAX 1 626 358 8048 ...