CHAPTER 3: USING PROGRAMMING FUNCTIONS
UNIFLOW
®
4 PULSED HEAT CONTROL
990-908
3-11
Item 4 on the menu,
PID CONTROL
, allows
the operator to fine tune the temperature
control. A PID CONTROL number in the
range of
100
to
269
can be selected from
the following table to achieve different
control features such as faster rise time or
less temperature overshoot. The default is
PID CONTROL
262
,
Item
5
on the menu,
SOLDER COOL
VALVE DELAY
, allows the operator to
< PID CONTROL >
PID CONTROL :
132
After edit
Page to accept new value
Number
Change,
◄►
Adjust,
Graph
/
Data
delay the turn-on of the Solder Cool Valve
after the end of the Reflow or Postheat periods. This single delay applies to both the end of Reflow and
Postheat periods. This parameter can be set from 0 to 9.9 seconds.
Selecting the PID CONTROL Number
The following table provides a guide to selection of a
PID CONTROL
number. It is recommended to start
with a
PID CONTROL
number of
185
. With this initial setting you can then optimize the
Coarse Heat
Rate
and
Fine Heat Rate
settings. After that you can return to the
PID CONTROL
number for additional
adjustments. For applications that require very fast rise of temperature with minimal overshoot, you'll
need to experiment with changes to all three control parameters:
PID CONTROL
,
COARSE HEAT RATE,
and
FINE HEAT RATE
.
The table of
PID CONTROL
numbers consists of two
separate sections.
Rows
A
through
K
typically
provide the best
PID CONTROL
number for most thermodes.
PID CONTROL
numbers in rows
L
through
Q
may provide better
performance for thermodes of
very low thermal mass or for
applications where additional
damping of oscillations is
needed.
When selecting a
PID CONTROL
number in rows
L
through
Q
it is
recommended to start with a
PID
CONTROL
number of
243
.
Содержание UNIFLOW 4 REMOTE
Страница 1: ...990 908 REV K PULSED HEAT CONTROL UNIFLOW 4 UNIFLOW 4 REMOTE OPERATION MANUAL ...
Страница 18: ...UNIFLOW 4 PULSED HEAT CONTROL xviii 990 908 ...
Страница 19: ...UNIFLOW 4 PULSED HEAT CONTROL 990 908 xix ...
Страница 20: ...UNIFLOW 4 PULSED HEAT CONTROL xx 990 908 ...
Страница 21: ...UNIFLOW 4 PULSED HEAT CONTROL 990 908 xxi ...
Страница 26: ......
Страница 36: ......
Страница 50: ......
Страница 96: ......
Страница 106: ......
Страница 137: ...UNIFLOW 4 PULSED HEAT CONTROL 990 908 C 1 APPENDIX C SYSTEM TIMING No Post Heat Pulse TCOOL1 Cool1 Temperature Setpoint ...
Страница 176: ...AMADA MIYACHI AMERICA INC 1820 South Myrtle Ave Monrovia CA 91016 U S A TEL 1 626 303 5676 FAX 1 626 358 8048 ...