APPENDIX A: TECHNICAL SPECIFICATIONS
UNIFLOW
®
4 PULSED HEAT CONTROL
990-908
A-5
Analog Inputs
Thermocouple
............................................................................................................... E, J, or K type
Thermocouple Extension Cables, Omega Standard:
Type E, Amada Miyachi America Part Number 10-355-02 ................................ 60 in. (152.4 cm)
Type J, Amada Miyachi America Part Number 10-355-02-02 ........................... 60 in. (152.4 cm)
Type K, Amada Miyachi America Part Number 10-355-02-01 .......................... 60 in. (152.4 cm)
Outputs
Audible Alarm
............................................................................................ Buzzer, volume adjustable
Course Heating Output Power (nominal) and Coarse Heating Output (secondary) Voltage
(nominal) at 120 VRMS or 240 VRMS transformer primary voltage:
STANDARD Versions
2 kVA transformer
(90 – 132 VAC
input single phase)
Secondary Voltage:
3.81V (Fast)
1.9V (Medium)
1.27V (Slow)
0.95V (Very Slow)
4 kVA transformer
(180-264 VAC
single phase input)
Secondary Voltage:
3.81V (Fast)
1.9V (Medium)
1.27V (slow)
0.95V (very slow)
4 kVA transformer
(180-264 VAC
single phase input)
Secondary Voltage:
7.62V (Fast)
3.8V (Medium)
2.54V (Slow)
1.90V (Very Slow)
2 kVA transformer
(180-264 VAC
single phase input)
Secondary Voltage:
3.81V (Fast)
1.9V (Medium)
1.27V (Slow)
0.95V (Very Slow)
2 kVA transformer
(180-264 VAC
single phase input)
Secondary Voltages:
7.62V (Fast)
3.8V (Medium)
2.54V (Slow)
1.90V (Very slow)
Model / Part Number
1-298-02
Model / Part Number
1-298-02-01
1-298-02-02
1-298-02-03
Model / Part Number
1-298-02-05
1-298-02-06
1-298-02-07
Model / Part Number
1-298-02-09
1-298-02-10
1-298-02-11
Model / Part Number
1-298-02-13
1-298-02-14
1-298-02-15
REMOTE Versions
4 kVA transformer
(180-264 VAC
single phase input)
Secondary Voltage:
3.81V (Fast)
1.9V (Medium)
1.27V (Slow)
0.95V (Very Slow)
4 kVA transformer
(180-264 VAC
single phase input)
Secondary Voltage:
7.62V (Fast)
3.8V (Medium)
2.54V (Slow)
1.90V (Very Slow)
2 kVA transformer
(180-264 VAC
single phase input)
Secondary Voltage:
3.81V (Fast)
1.9V (Medium)
1.27V (Slow)
0.95V (Very Slow)
2 kVA transformer
(180-264 VAC
single phase input)
Secondary Voltages:
7.62V (Fast)
3.8V (Medium)
2.54V (Slow)
1.90V (Very Slow)
Model: Part Number
X4/240UNF:
9-040-01
Model: Part Number
X4/240UNFHV:
9-041-01
Model: Part Number
X2/240UNF:
9-042-01
Model: Part Number
X2/240UNFHV:
9-043-01
Содержание UNIFLOW 4 REMOTE
Страница 1: ...990 908 REV K PULSED HEAT CONTROL UNIFLOW 4 UNIFLOW 4 REMOTE OPERATION MANUAL ...
Страница 18: ...UNIFLOW 4 PULSED HEAT CONTROL xviii 990 908 ...
Страница 19: ...UNIFLOW 4 PULSED HEAT CONTROL 990 908 xix ...
Страница 20: ...UNIFLOW 4 PULSED HEAT CONTROL xx 990 908 ...
Страница 21: ...UNIFLOW 4 PULSED HEAT CONTROL 990 908 xxi ...
Страница 26: ......
Страница 36: ......
Страница 50: ......
Страница 96: ......
Страница 106: ......
Страница 137: ...UNIFLOW 4 PULSED HEAT CONTROL 990 908 C 1 APPENDIX C SYSTEM TIMING No Post Heat Pulse TCOOL1 Cool1 Temperature Setpoint ...
Страница 176: ...AMADA MIYACHI AMERICA INC 1820 South Myrtle Ave Monrovia CA 91016 U S A TEL 1 626 303 5676 FAX 1 626 358 8048 ...