3 . Name and Function of Each Section on the Lateral Side and Rear Side
35
MF-C300A-SF/C500A-SF
Introduction Part
Inst
allat
ion and
Preparation Part
Operating Part
Maintenance Part
Appendixes
Chapter 2 Name and Functions of Each Section
(11) THMON Con-
nector
Not used.
(12) PWRMON Con-
nector
BNC connector used to output an analog signal representing the monitor
waveform of laser power. When viewing the waveform of laser output,
connect to an oscilloscope.
The output range is 0 to 5 V (MF-C300A-SF: 300 W = 4 V, MF-C500A-
SF: 500 W = 4 V). Set the impedance of the oscilloscope to 1 MΩ.
(13) CH .I/L Connec-
tor
Not used.
(14)
TH Connector
Not used.
(15) R .MNT Connec-
tor
Not used.
(16)
E-STOP Con-
nector
Used to connect to the Remote Interlock for emergency stop or input/
output Emergency signals.
(17) RS-485 (1), (2)
Connectors
Connects a personal computer to use the external communication function.
Содержание MF-C300A-SF
Страница 1: ...AA03OM1193140 12 FIBER LASER WELDER MF C300A SF C500A SF OPERATION MANUAL Original instructions...
Страница 20: ......
Страница 21: ...Introduction Part...
Страница 22: ......
Страница 36: ......
Страница 37: ...Installation and Preparation Part...
Страница 38: ......
Страница 42: ......
Страница 50: ......
Страница 51: ...Operating Part...
Страница 52: ......
Страница 114: ......
Страница 159: ...Maintenance Part...
Страница 160: ......
Страница 176: ......
Страница 177: ...Appendixes...
Страница 178: ......
Страница 182: ...182 MF C300A SF C500A SF Dimensional Outline Drawings Fiber Connector Unit mm Max diameter incl the removable gaiter...