130
MF-C300A-SF/C500A-SF
3 . Connector Functions
When Using an Open-Collector Signal
10k
10k
TLP180
TLP197G
24V
EXT 0V
RY
EXT. I/O(1): 2 to 6, 25
EXT. I/O(2): 27 to 34
EXT. I/O(1): 11 to 17,
20, 22, 23
EXT. I/O(2): 3
EXT. I/O(1): 21
EXT. I/O(2): 14
EXT. I/O(1): 19
EXT. I/O(1): 9
EXT. I/O(1): 1
EXT. I/O(1): 10
EXT. I/O(2): 35
4.7k
4.7k
TLP180
EXT +24V
+24V
output
0V
output
*1
*1
Normally
closed for
Laser Stop
Load
Inside of the laser
Input circuit
Output circuit
Output COM
Input COM
Emergency
stop