5 . Monitoring Output
103
MF-C300A-SF/C500A-SF
Chapter 2 V
arious Settings
Introduction Part
Inst
allat
ion and
Preparation Part
Operating Part
Maintenance Part
Appendixes
- When the waveform is set with less than 1 ms of pulse width, the average power
displayed in "AVERAGE" may differ from the actual laser output power.
- When the set time exceeds 100 seconds in the CW waveform, the waveform
shows trends in the past 100 seconds .
Setting the Laser Energy Range To Be Monitored
Set the upper limit value and lower limit value of energy to be monitored. This set
range is used as the allowable energy range.
(1) Press the "HIGH" setting button.
Enter the upper limit value by using the numeric keypad and then press the ENT
key.
The upper limit value of allowable energy is registered.
(2) Press the "LOW" setting button.
Enter the lower limit value by using the numeric keypad and then press the ENT
key.
The lower limit value of allowable energy is registered.
⇒
When laser light is out of the set allowable energy range, error No.035/LASER
POWER OUT OF RANGE occurs and a monitor trouble is output. (Pin No.20 of
the EXT. I/O (1) connector is closed for the time set on the CONFIG screen after
a laser output.) When the total laser output time is 0.5 s or less in the CW mode,
however, a monitor trouble does not occur even if laser light is out of the range.
⇒
When the total laser output time is higher than 0.5 s in the CW mode, set
“HIGH” and “LOW” at the ratio of output (SET POWER × POWER [%]) set on
the SCHEDULE screen. The following formula is given to convert the set value
into Watts. POWER [%] is also increased or decreased according to the output
increase/decrease between each POINTs. When the measured value of the
monitored laser light is out of the range shown by red lines below, error No.035/
LASER POWER OUT OF RANGE occurs.
Содержание MF-C300A-SF
Страница 1: ...AA03OM1193140 12 FIBER LASER WELDER MF C300A SF C500A SF OPERATION MANUAL Original instructions...
Страница 20: ......
Страница 21: ...Introduction Part...
Страница 22: ......
Страница 36: ......
Страница 37: ...Installation and Preparation Part...
Страница 38: ......
Страница 42: ......
Страница 50: ......
Страница 51: ...Operating Part...
Страница 52: ......
Страница 114: ......
Страница 159: ...Maintenance Part...
Страница 160: ......
Страница 176: ......
Страница 177: ...Appendixes...
Страница 178: ......
Страница 182: ...182 MF C300A SF C500A SF Dimensional Outline Drawings Fiber Connector Unit mm Max diameter incl the removable gaiter...