174
MF-C300A-SF/C500A-SF
1 . Error Display and How to Take a Measure
No .
Contents of error
LD
Alarm
output
Measures
207
LDPS MONITOR VOLTAGE HIGH
OFF
ON
Abnormal voltage of the LD unit.
Consult us.
210
INTERNAL UNIT TEMP WARNING
(W01)
-
-
Temperature inside the equipment is high.
Secure spaces for air intake at the front and ex-
haust at the rear. If the air filter is dirty, clean it.
211
BACK REFLECTION HIGH (W03)
-
-
It's too strong back reflection.
Adjust the power setting to reduce back reflection.
212
LD POWER SUPPLY WARNING
(W05)
OFF
ON
Abnormal voltage of the LD unit.
If it has not been better by restarting, consult us.
214
BACK REFLECTION HIGH ERROR
(A01)
OFF
ON
It's too strong back reflection.
Adjust the power setting to reduce back reflection.
215
INTERNAL UNIT TEMP ERROR
(A02)
OFF
ON
Temperature inside the equipment is high.
Secure spaces for air intake at the front and ex-
haust at the rear. If the air filter is dirty, clean it.
Installation temperature may be high. Place LASER
in an atmosphere under the specification.
216
LD CURRENT HIGH (A03)
OFF
ON
Restart the LASER.
If this error happens often, consult us.
217
OUTPUT POWER LOW(A04)
OFF
ON
The optical circuit is wrong.
Consult us.
218
ILLEGAL USE (A05)
-
-
Invalid operation in self-checking at warming-up.
Restart in accordance with the operation manual.
219
FIBER OUTPUT UNIT ERROR
(A06)
OFF
ON
Check the feed fiber broken.
Check that the optical fiber is connected correctly.
If you can't reset this error, consult us.
220
ENGINE ERROR (A08)
OFF
ON
The communication error occurs between internal
units.
If this error happens often by restarting, consult us.
221
OUTPUT POWER HIGH (A10)
OFF
ON
The power output is too high. → P.167
Adjust the power setting to reduce back reflection.
222
INTERNAL UNIT OPEN (A14)
OFF
ON
The cover of inner unit is opened.
Consult us.
226
CABINET TEMP. HIGH ERROR
OFF
ON
The temperature in the cabinet is too high.
If it has not been better by lowering the tempera-
ture of installation environment, consult us.
230
SURROUNDING TEMP WARNING
(W02)
-
-
Check the air intake-and-exhaust system or instal-
lation environment.
If this error happens often by restarting, consult us.
231
INTERNAL UNIT COOLING-FAN
WARNING (W09)
-
-
Turn off the power and clean the fan at the rear of
the main unit.
The fan may come to the end of its service life.
Consult us.
Содержание MF-C300A-SF
Страница 1: ...AA03OM1193140 12 FIBER LASER WELDER MF C300A SF C500A SF OPERATION MANUAL Original instructions...
Страница 20: ......
Страница 21: ...Introduction Part...
Страница 22: ......
Страница 36: ......
Страница 37: ...Installation and Preparation Part...
Страница 38: ......
Страница 42: ......
Страница 50: ......
Страница 51: ...Operating Part...
Страница 52: ......
Страница 114: ......
Страница 159: ...Maintenance Part...
Страница 160: ......
Страница 176: ......
Страница 177: ...Appendixes...
Страница 178: ......
Страница 182: ...182 MF C300A SF C500A SF Dimensional Outline Drawings Fiber Connector Unit mm Max diameter incl the removable gaiter...