CHAPTER 5: PROGRAMMING MODES
2 KHZ INVERTER WEDLING POWER SUPPLY
990-057
5-3
ALARM State
The Power Supply automatically recognizes
many alarm conditions which are described in
detail under
Appendix C, Alarm Messages
. The
ALARM FIRING SWITCH
screen shown on the right
is displayed when the Firing Switch of an
AMADA WELD TECH Air Actuated Weld Head
does not close within 10 seconds.
FIRE State
Once weld current is flowing, the Power Supply
is in the Fire State. Weld current can be
terminated by: (a) removing the first level of a
single-level Foot Switch; (b) removing the second
level of a two-level Foot Switch; or (c) shorting
the Emergency Stop Control Signals Input Pin 10
to Pin 11. Completion of the Firing State is
indicated by momentary appearance of the END
status message as shown in the example to the
right.
MENU State
Pressing
MENU
puts the Power Supply in the
MENU
State, which offers you different options
common to all weld schedules such as how the
Power Supply interfaces with the Firing Switch,
Foot Switch, and Weld Head. Like a tree with
many branches, there are multiple Menu levels.
Each new level is accessed by making an option
selection, then pressing
ENTER
. To return to a
previous Menu level, press
MENU
. For a complete
description on Menu Options, refer to
Chapter 7,
System Options.
Содержание HF2
Страница 1: ...990 057 REV S INVERTER WELDING POWER SUPPLY HF2 HF2S OPERATION MANUAL...
Страница 24: ......
Страница 44: ......
Страница 56: ......
Страница 64: ......
Страница 104: ......
Страница 106: ......
Страница 112: ......
Страница 114: ......
Страница 134: ...AMADA WELD TECH INC 1820 South Myrtle Ave Monrovia CA 91016 U S A TEL 1 626 303 5676 FAX 1 626 358 8048...