CHAPTER 3: WELDING SYSTEM SET-UP
2 KHZ INVERTER WEDLING POWER SUPPLY
990-057
3-13
25
Turn the Air Regulator that feeds the Top
Right Air Cylinder on the Right Weld
Head Clockwise (CW) until the Power
Supply automatically returns the Upper
Electrode to its up position. The lower
right hand corner of the display should
now show the status message END if
you have not released the Foot Switch.
Release the Foot Switch.
NOTE:
You have 10 seconds to make
the Air Regulator adjustment or a buzzer
alarm will sound and the Power Supply
will automatically return the Upper
Electrode to its up position. The status
message changes from
STANDBY
to
ALARM FIRING SWITCH
. Press
RUN
to
clear the alarm, then repeat steps 24 and
25.
26
Re-adjust the Air Regulator that feeds the Bottom Right Air Cylinder on the Right Weld Head to
produce the same air pressure as finally used on the Top Air Regulator on the Right Weld Head.
27
Adjust the Right Weld Head Down Speed Control Knob so the Right Weld Head Upper Electrode
descends smoothly onto the parts.
28
Adjust the Right Weld Head Up Speed Control Knob so that the Right Weld Head Upper
Electrode Holder does not impact upon returning to in up position.
29
Press
▼
to select
SCH:001 BASIC WELD
. You are now ready to adjust the Left Weld Head Air
Regulators.
30
Repeat steps 24 through 29 for the Dual Air Weld Head System, All Regulator Adjustments for
the Left Weld Head.
Содержание HF2
Страница 1: ...990 057 REV S INVERTER WELDING POWER SUPPLY HF2 HF2S OPERATION MANUAL...
Страница 24: ......
Страница 44: ......
Страница 56: ......
Страница 64: ......
Страница 104: ......
Страница 106: ......
Страница 112: ......
Страница 114: ......
Страница 134: ...AMADA WELD TECH INC 1820 South Myrtle Ave Monrovia CA 91016 U S A TEL 1 626 303 5676 FAX 1 626 358 8048...