CHAPTER 2: GENERAL SETUP
2 KHZ INVERTER WEDLING POWER SUPPLY
990-057
2-3
HF2 Welding Transformer Electrical Specifications
Model
Input Volts
(rms)
Input kVA
(rms)
Duty Cycle (%) Peak Open Ckt
Output Voltage
Peak Output
Max. (Amps)
Max Sec
Resist. (
µΩ
)
IT-X3A/4/380A
380
9
6
6.5
4,000
500
IT-X3A/4/460A
460
9
6
6.5
4,000
500
IT-X3A/4000A
230
9
6
6.5
4,000
500
IT-X11A/4/460A
380
4
5
11.8 (44:1 TR)
10.0 (52:1 TR)
8.6 (60:1 TR)
7.5 (68:1 TR)
4,000
4,000
4,000
4,000
1,300
1,100
950
825
460
4
5
14.3 (44:1 TR)
12.1 (52:1 TR)
10.5 (60:1 TR)
9.2 (68:1 TR)
4,000
4,000
4,000
4,000
1,300
1,100
950
825
IT-X11A/4000A
230
15
5
10.7
10.0 (52:1 TR)
8.6 (60:1 TR)
8.7
8.8
8.9
4,000
4,000
4,000
1,300
1,100
TRANSFORMER SPECIFICATION NOTES
:
1
For the IT-X11A/4/460A transformer, the
turns ratios (TR) is selectable by a switch on
the transformer rear panel.
2
Power Supply Input voltage selection must
be jumpered at E12 on the HF2 Power
Supply PCB as shown in Figure 2-3. E12 is
located at the center of the PCB left edge.
3
Maximum weld time at Maximum Short
Circuit Current is 50 milliseconds.
Figure 2-3. Voltage Jumpers
No Jumper = 230 V
Upper Jumper = 380 V
Lower Jumper = 460 V
Содержание HF2
Страница 1: ...990 057 REV S INVERTER WELDING POWER SUPPLY HF2 HF2S OPERATION MANUAL...
Страница 24: ......
Страница 44: ......
Страница 56: ......
Страница 64: ......
Страница 104: ......
Страница 106: ......
Страница 112: ......
Страница 114: ......
Страница 134: ...AMADA WELD TECH INC 1820 South Myrtle Ave Monrovia CA 91016 U S A TEL 1 626 303 5676 FAX 1 626 358 8048...