CHAPTER 3: WELDING SYSTEM SET-UP
2 KHZ INVERTER WEDLING POWER SUPPLY
3-10
990-057
3
2-Level Foot Switch
-- When a 2-Level Foot Switch is pressed to the first level, the Power
Supply energizes the Air Actuated Weld Head, causing the Upper Electrode to descend and apply
force to the parts. If the Foot Switch is released before the operator presses the Foot Switch to
the second level, the Power Supply will automatically return the Upper Electrode to its up
position so that the parts can be repositioned. Once the second level has been reached and the
Force Firing Switch in the Weld Head has closed, Weld Current will flow and the Power Supply
will automatically return the Upper Electrode to its up position.
Dual Air Regulator Adjustment (Model 188 - Figure 3-5)
1
Set the Power Supply front panel
WELD/NO WELD
switch to
NO WELD
.
2
Turn the Power Switch located on the
Power Supply rear panel to
ON
. After a
series of power up screens, the last
RUN
screen displayed will appear. Press the
CHNG
key to access the Weld Graph
RUN
screen for the
BASIC WELD
Function.
3
Press
MENU
. The
MAIN MENU
screen
will appear.
4
Select
TRANSFORMER MODEL
. The
TRANSFORMER MODEL
screen appears.
5
Select
MULTIPLE HEADS: OFF
. If the
display reads
ON
, press
CHNG
until
OFF
is displayed.
6
Select
HEAD 1: X3/4000-230
.
The IT-X3A/230 is the default
Transformer Model. Press
CHNG
until
the correct Transformer Model that you
have purchased appears.
7
Press
MENU
to return to the
MAIN MENU
screen.
Содержание HF2
Страница 1: ...990 057 REV S INVERTER WELDING POWER SUPPLY HF2 HF2S OPERATION MANUAL...
Страница 24: ......
Страница 44: ......
Страница 56: ......
Страница 64: ......
Страница 104: ......
Страница 106: ......
Страница 112: ......
Страница 114: ......
Страница 134: ...AMADA WELD TECH INC 1820 South Myrtle Ave Monrovia CA 91016 U S A TEL 1 626 303 5676 FAX 1 626 358 8048...