CHAPTER 6: MAINTENANCE
HF28 DC RESISTANCE WELDING SYSTEM
990-372
6-7
Alarm Message
Description
Corrective Action
SYSTEM
PARAMETERS ARE
RESET
User programmed the HF28 to
automatically reset all I/O and other
system parameters to their factory set
default values.
CAUTION:
Be careful when using the MENU
default features. There is no way to restore a
default action.
SYSTEM &
SCHEDULE RESET
TO DEFAULTS
User programmed the HF28 to
automatically reset all 100 weld
schedules, I/O and other system
parameters to their factory set default
values.
CAUTION:
Be careful when using the MENU
default features. There is no way to restore a
default action.
UPSLOPE
REQUIRED FOR
LOWER LIMIT
User has programmed a Lower Limit
value for Weld1 or Weld2 periods
without using an upslope period. The
HF28 will automatically stop when
activated because the starting weld
energy will always be lower than the
Lower Limit.
Delete the Weld1 or Weld2 Lower Limit value.
Add an upslope period before Weld1 or Weld2 if
a Lower Limit value is desired.
VOLTAGE 1
GREATER THAN
UPPER LIMIT
Actual weld voltage is greater than the
user set Upper Limit value for Weld1.
Weld splash can cause the actual weld voltage to
exceed the user set Upper Limit for Weld1. Add
upslope to reduce weld splash.
Reset the Upper Limit for Weld1 to a larger
value.
VOLTAGE 2
GREATER THAN
UPPER LIMIT
Actual weld voltage is greater than the
user set Upper Limit value for Weld2.
Weld splash can cause the actual weld voltage to
exceed the user set Upper Limit for Weld2. Add
upslope to reduce weld splash.
Reset the Upper Limit for Weld2 to a larger
value.
VOLTAGE 1
LOWER THAN
LOWER LIMIT
Actual weld voltage current is less than
the user set Lower Limit value for
Weld1.
Reduce the weld cable length or increase the
diameter of the weld cables.
Reset the Lower Limit for Weld1 to a smaller
value.
VOLTAGE 2
LOWER THAN
LOWER LIMIT
Actual weld voltage current is less than
the user set Lower Limit value for
Weld2.
Reduce the weld cable length or increase the
diameter of the weld cables.
Reset the Lower Limit for Weld2 to a smaller
value.
VOLTAGE
SELECTION PLUG
IS MISSING
The Voltage Selection Plug on the Weld
Transformer is missing or improperly
connected.
Verify the Voltage Selection Plug connection on
the Weld Transformer.
Содержание 1-288-01
Страница 1: ...990 372 REV E DC RESISTANCE WELDING SYSTEM HF28 OPERATION MANUAL...
Страница 10: ...HF28 DC RESISTANCE WELDING SYSTEM x 990 372...
Страница 64: ......
Страница 88: ......
Страница 102: ......
Страница 114: ......
Страница 142: ......
Страница 144: ...AMADA MIYACHI AMERICA INC 1820 South Myrtle Ave Monrovia CA 91016 U S A TEL 1 626 303 5676 FAX 1 626 358 8048...