APPENDIX A. TECHNICAL SPECIFICATIONS
HF28 DC RESISTANCE WELDING SYSTEM
A-2
990-372
Performance Capabilities
Number of Weld Schedules
...................................................................................................................100
Programmable Weld Periods:
Squeeze
.................................................................................................................................0 - 999 ms
Upslope
1
.................................................................................................................................0 - 99 ms
Weld
1
...................................................................................................................................0 - 99 ms
Downslope
1
............................................................................................................................0 - 99 ms
Cool
...................................................................................................................................0 - 99 ms
Upslope 2 ................................................................................................................................0 - 99 ms
Weld
2
...................................................................................................................................0 - 99 ms
Downslope
2
............................................................................................................................0 - 99 ms
Hold
.................................................................................................................................0 - 999 ms
Weld Head System Compatibility
Force Fired, Foot Actuated
Force Fired, Single Valve Air Actuated
Non Force-Fired, Single Valve Air or Cam Actuated
Force
Fired,
EZ Air
Kit
Plug-and-Play
24VDC
EZ-AIR
weld head
301/350 Series Electronic Weldheads
Weld Energy Limits Monitoring
Weld Pre-Check Mode:
Inhibit second weld pulse when first test pulse exceeds programmed
limits.
Measurement Parameters:
Current, voltage and power.
Measurement Selection:
Peak or average.
Measurement Range and Accuracy
:
Parameter
Range
Accuracy
Current
0.1 - 2.4 kA
± (2% of s2A)
Voltage
0.2 - 9.999 V
± (2% of s0.02V)
Power
0.05 - 9.999 kW
± (5% of s10W)
Limit Ranges:
Same as the measurement ranges
Alarms:
Display alert and two programmable AC/DC relay contact outputs.
Содержание 1-288-01
Страница 1: ...990 372 REV E DC RESISTANCE WELDING SYSTEM HF28 OPERATION MANUAL...
Страница 10: ...HF28 DC RESISTANCE WELDING SYSTEM x 990 372...
Страница 64: ......
Страница 88: ......
Страница 102: ......
Страница 114: ......
Страница 142: ......
Страница 144: ...AMADA MIYACHI AMERICA INC 1820 South Myrtle Ave Monrovia CA 91016 U S A TEL 1 626 303 5676 FAX 1 626 358 8048...