CHAPTER 2: INSTALLATION AND SETUP
HF28 DC RESISTANCE WELDING SYSTEM
2-2
990-372
Utilities
Power
Because of the different electrical requirements for the countries in which the Control is used, the
Control is shipped without a power cable connector. The required connections for your power cable
connector are described in
Appendix B, Electrical and Data Connections.
Input power requirements for
the Control are as listed below.
Power Input Specifications
HF28 Model
Input Voltage,
50-60 Hz,
3 phase
(Vrms)
Ckt Brkr
Current (A rms)
Copper Wire
Gauge,
7 strands (AWG)
Wire Dia
(mm)
Fuses F1, F2
Amps/
Volts
AMADA
MIYACHI
AMERICA
P/N
HF28/240 240
25
10 2.5
6.3
330-096
HF28/400 400
20
10 2.5
3.15
330-095
HF28/480 480
13
10 2.5
3.15
330-097
Compressed Air and Cooling Water
If you require compressed air and cooling water service for the weld head, please refer to the weld head
manufacturer’s user’s manual for service specifications.