CHAPTER 3: SYSTEM CONFIGURATION
HF28 DC RESISTANCE WELDING SYSTEM
990-372
3-7
2. RESET ALL SCHEDULES
1.
Press the
2
key. This will
automatically reset all weld schedule
parameters to the factory defaults and
return the screen to the
RESET TO
DEFAULTS
display.
2.
Press the
MENU
key to return to the
MAIN MENU
screen.
<RESET ALL SCHEDULES?>
1. NO
2. YES
Number Select, Page, RUN or MENU
3. RESET SCHEDULE LIMITS
1.
The last
SCHEDULE
you used will
appear as
highlighted
. You may
change this to any
SCHEDULE
number
you want to reset using the numeric
keypad.
2.
Press the key to reset the limits of the
schedule you highlighted.
<RESET SCHEDULE LIMITS>
SCHEDULE
:
01
PUSH TO RESET THIS SCHEDULE’S LIMIT VALUES
Number Select an item,
Page, RUN or MENU
3.
Press the
MENU
key to return to the
MAIN MENU
screen.
8. CHAIN SCHEDULES
This feature allows you to automatically change from any weld schedule to any other schedule after a
preset count, creating a "chain" of schedules that can accommodate a variety of welding needs. For
example:
A single work piece requires four welds, two weld points require the same weld schedule, each
of the other two points require different weld schedules.
In this case you would program a sequence, or "chain," that looks like this:
Schedule 01
[2
times] -
Schedule 02
[1 time] -
Schedule 03
[1 time] -
Schedule 01
. This sequence will
repeat, or "loop," until you turn
Chain Schedules OFF
.
Some applications require a lower current for a number of welds after the electrodes have been
replaced or resurfaced. Once the electrodes have been “seasoned”, the current can be increased
as required. If the electrodes require 100 welds to “season”, Schedule 01 can be programmed
with a lower current and Schedule 02 can be programmed with a higher current. The chain
would look like this:
Schedule 01
[100 times] -
Schedule 02
[1 time] -
Schedule 02
[1 time].
In this chain,
Schedule 02
will just keep repeating
after
the 100 welds made using
Schedule 01
.
When the electrodes are replaced or resurfaced, you can manually switch back to
Schedule 01
to restart the sequence.
Содержание 1-288-01
Страница 1: ...990 372 REV E DC RESISTANCE WELDING SYSTEM HF28 OPERATION MANUAL...
Страница 10: ...HF28 DC RESISTANCE WELDING SYSTEM x 990 372...
Страница 64: ......
Страница 88: ......
Страница 102: ......
Страница 114: ......
Страница 142: ......
Страница 144: ...AMADA MIYACHI AMERICA INC 1820 South Myrtle Ave Monrovia CA 91016 U S A TEL 1 626 303 5676 FAX 1 626 358 8048...