APPENDIX B: ELECTRICAL AND DATA CONNECTIONS
HF28 DC RESISTANCE WELDING SYSTEM
990-372
B-3
Pin Signal
Name
Description
11
24COM
NEGATIVE of internal 24 VDC power supply
12
SCHEDULE 8
Binary Schedule input terminals, used for schedule selection
13
RELAY_2R
Return of RELAY_2
14
NOT ACTIVE
15
RELAY_1R
Return of RELAY_1
Two-Level Foot Switch Connector
When you press the foot switch to the first level, the Control energizes the air actuated weld head. This
causes the upper electrode to descend and apply force to the weld pieces. If you release the foot switch
before pressing it to the second level, the Control will automatically return the upper electrode to its UP
position so that you may re-position the weld pieces.
If you do not release the foot switch at the first level and proceed to the second level, the force-firing
switch in the weld head will close. Weld current will flow, and the Control will automatically return the
upper electrode to its UP position.
Using the supplied Configuration plug on Pins 11 – 20 allows the use of the Miyachi Unitek 2-level
footswitch directly. If a PLC or other means of trigger is used, refer to the
I/O Signal Interface General
Description
on page B-3.
Foot Switch Connector
Pin Description
1
Chassis Ground
2
Foot_1 (to activate Foot Switch Level 1, connect to pin 4 )
3
Foot_2 (to activate Foot Switch Level 1, connect to pin 4 )
4
24COM
Содержание 1-288-01
Страница 1: ...990 372 REV E DC RESISTANCE WELDING SYSTEM HF28 OPERATION MANUAL...
Страница 10: ...HF28 DC RESISTANCE WELDING SYSTEM x 990 372...
Страница 64: ......
Страница 88: ......
Страница 102: ......
Страница 114: ......
Страница 142: ......
Страница 144: ...AMADA MIYACHI AMERICA INC 1820 South Myrtle Ave Monrovia CA 91016 U S A TEL 1 626 303 5676 FAX 1 626 358 8048...